NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 03/26/09
Floor iZip Borough Block Lot Squad # Badge #
Various 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M Gagnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 8:30 am to 9:35 am
I arrived at the premise at 8:30 am. LVI schedule informed that activities include: scrape fireproofing, clear off
floor on S'^floor, clear off floor, scrape fireproofing, erect platforms various locations on 2""' floor, clear floor,
cut ducts, demo walls, ceilings on 1^’ floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to
enter the regulated area on S'^loor.
One worker was present for the decon maintenance, cleaning and organizing the clean room. Negative air
pressure on the floor was -0.033.
3'“ Floor - I observed 35 workers on the floor. Fireproofing removal at the areas 9-10 was completed, workers
were washing and cleaning beams, columns, platforms of the scaffolds, picking up debris from the floor, placing
into the boxes, cleaning the floor. Workers were plasticizing the floor and critical barriers of the area 13
preparing for fireproofing removal. Others were preparing boxes.
3 sealed Gaylord boxes were on the floor. 20 Micro trap machines were powered on and 5 on stand by.
Inspection was done on micro trap tents.
I used B stairwell to proceed to the 2"“ floor.
2"'' Floor - 48 workers were found inside the work area, scraping fireproofing and spraying with amended
water at the area 9 of the high ceiling vestibule. At the west side of vestibule two workers were harnessed in
scissor lift demolishing metal and glass partition. Fireproofing removal at the hallways 10 and 11 was
completed and workers were washing and cleaning poly of the critical barriers, picking up gross debris,
cleaning the floor. Other workers were plasticizing the floor at the shaft area, preparing boxes.
8 Gaylord boxes were on the floor sealed, sprayed and ready for load out. 22 micro trap machines were
powered on and 5 on stand by. Inspection was done on micro trap tents.
I used B stairwell to proceed to the 1^’ floor.
1’* Floor - 67 workers were on the floor. Workers in scissor lifts, wearing harnesses and attached to a life
safety line, were cutting pipes, air ducts, metal fixtures from the ceiling at the various locations of the work area,
removing insulation, cutting and demolishing metal partition; cutting conduit and clearing off shafts, placing
debris into the boxes and spraying with amended water; cutting metal at the various locations into the pieces,
wrapping beams, preparing and loading out boxes through the waste decon. Inside of mechanical room two
workers were observed taking apart conditioner; workers on mezzanine were demolishing metal frame and
glass partition. A large amount of debris and poly wrapped beams exists on the floor.
15 Gaylord boxes were on the floor ready for load out. Inspection was done on micro trap machines and tents.
I used B stairwell to proceed to the 3'“ floor.
After following the decontamination procedure I signed the log book and used south hoist to return to the
ground floor.
Inspection was done on ATC trailers.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial , ,
Borough 1 “Manhattan 2=Bronx 3=Brooklyn 4=Queens .'“Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2“TJo Violation Issued 3“No access 4“Project not started (no NOV)
5=Public Owned Property
C ITY_D EP_WO RBY_C AN NAT A SU B POO0131190
NYC-WTC_000182028
OCR can misread numbers and units. Confirm readings against the page image before using them.