NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 03/07/09
Floor Zip Borough Block Lot Squad # Badge #
Various 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor's Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from;
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 1:50 pm to 2:55 pm
I arrived at the premise at 1:50 pm. LVI schedule informed that activities include: remove walker ducts and
raceways on 6*’’ floor, scrape fireproofing, clear off floor, temp platforms in shaft on S'^floor, demo walls,
clear off floor, scrape fireproofing, erect platforms various locations on 2"“ floor, clear floor, cut ducts,
demo walls, ceilings on floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment
to enter the regulated area on 2"'^floor. Two workers were present for the decon maintenance.
I used B stairwell to proceed to the 3'^ floor.
3"* Floor - 38 workers were present. Fireproofing removal at the area 5 has been completed; workers on
scaffolds were cleaning the ceilings, beams, washing scaffolds, picking up debris, cleaning and sweeping the
water from the floor, placing debris into the boxes, cutting edges at the shaft area to clean the floor and
platforms. Others were cutting metal with tools attached to HEPA vacuum, placing into the boxes and spraying
with amended water. 35 Gaylord boxes were sprayed with amended water and ready for load out. Inspection
was done on micro trap machines and tents.
I used B stairwell to proceed to the 2"'’ floor.
2"'^ Floor - 58 workers were found inside the work area. Fireproofing removal was completed at the area 5.
Workers were cleaning the ceilings and beams, washing equipment, scaffolds inside the shaft area, spraying
with amended water, picking up debris, cleaning the floor. Other workers were cutting metal using tools
attached to the HEPA vacuum, wrapping beams with poly, preparing boxes. 30 Gaylord boxes were on the floor
sealed, sprayed and ready for load out. 35 micro trap machines were powered on and 5 on stand by. Inspection
was done on micro trap tents.
I used B stairwell to proceed to the Y'floor.
1’‘ Floor - 72 workers were inside the work area. Platinum Electricians were inside the mechanical room
working with electrical cables, two other workers were plasticizing the frame of the engine machine. Workers on
scissor lifts were cutting and demolishing air ducts at the various locations, removing heating pipes;
demolishing the brick wall on the east side of the work area, spraying with amended water; workers on scissor
lifts were removing hard concrete drop ceiling, clearing shafts, placing debris into the boxes and spraying with
amended water, cutting metal at the various locations into the pieces, preparing, wrapping and loading out
boxes through the waste decon. A large amount of debris and poly wrapped beams exists on the floor.
18 Gaylord boxes were on the floor ready for load out. Inspection was done on micro trap machines and tents.
I used B stairwell to go back to the S'^ifloor.
After following the decontamination procedure I signed the log book and used north hoist to return to the
ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhanan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned.
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property