NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No, Inspection Date:
130 Liberty Street 02/16/09
Floor Zip Borough Block Lot Squad # Badge #
Various_________ 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M,Gagnidze_____ F TRU2068MN08 yes
Contractors Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner's Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr, Proj. Mgr/TRC Environmental 2:25 pm to 3:25 pm
I arrived at the premise at 2:25 pm, proceeded to the decon, signed the log book, don the appropriate level of
personal protective equipment to enter the regulated area on 4“’ floor. Negative air pressure on the floor was
0.038. One worker was present for the decon maintenance.
A*” Floor - 25 workers were present on the floor, wrapping and elevating the electrical cables, washing,
sweeping and vacuuming the floor at the north/east side of the work area with equipment equipped with HEPA
filters, fine cleaning horizontal and vertical surfaces at the spandular beams, clearing off the floor, preparing for
visual inspection. 4 Gaylord boxes were ready to be taken out. Inspection was done on micro trap machines
and tents.
I used B stairs to proceed to the 3"Tloor.
3'^^' Floor - 28 workers were working on the floor, demolishing the sheetrock wall between two shafts; taking
down drop ceiling to remove the insulation and cut and demolish the air duct at the east and north side of the
area; workers on the scissor lift were in the process of removing air ducts, removing metals from the ceiling at
the east side vestibule, wrapping beams with poly, cutting metal using the tools with HEPA vacuum attached,
cutting pipes on the floor at the north/west side vestibule. Others were loading out boxes and poly wrapped
beams, picking up debris, preparing boxes. 12 Gaylord boxes were ready to be taken out. Inspection was done
on micro trap machines and tents.
I used B stairwell to proceed to the 2"'^ floor.
2'"' Floor - 53 workers were found inside the work place, demolishing the air ducts and pipes inside the
mezzanine, located between 2'"’ and V' floors; plasticizing the platforms, built above the escalator shaft at the
east side of the area; cutting pipes and metal fixtures from the ceiling at the shaft, demolishing stairs at the
south/east side. Others cutting metal into the pieces, using power tool with HEPA vacuum attached, spraying
the area with amended water, removing metal ceiling components; picking up debris from the floor, placing into
the boxes and spraying with amended water, wrapping beams with poly, preparing boxes. 15 Gaylord boxes
were on the floor sealed, sprayed and ready for load out. Filters of micro trap machines were dirty. Handler
Supervisor was advised, and 2 workers replaced the filters. 35 micro trap machines were powered on and 5 on
stand by. Inspection was done on micro trap tents.
I used B stairwell to proceed to the 1'* floor.
1” Floor - 34 workers were clearing off the floor. Workers on ladders and scissor lifts were cutting air ducts,
demolishing the wall at the north side, cutting debris and placing into the boxes, spraying the work areas with
amended water, preparing, wrapping and loading out boxes through the waste decon, A large amount of debris
and poly wrapped beams exists on the floor. 15 sealed and 10 open Gaylord boxes were on the floor.
I used B stairwell to proceed to the 4*^ floor.
After following the decontamination procedure I signed the log book and used south hoist to return to the
ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2____________________
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhattan 2=Bronx 3-Brooklyn 4=Queens 5=Richmond
Building Type -A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000131202