NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street______ 05/18/09
"Floor Zip Borough Block Lot Squad # Badge #
Various ' 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gaqnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
462 Getty Avenue Clifton
State Zip Phone Sample Number
NJ 07011 973-772-3660
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 10:00 am to 11:00 am
I arrived at the premise at 10:00 am. LVI schedule informed that activities include: scraping Atrium area on 2"''
floor, clear floor, cut ducts, pipes, scrape fireproofing South East side. Eagle scaffolding - erect platforms in
various shafts, loading out boxes to ATC trailer on 1®‘ floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to
enter the regulated area on 3"’loor.
One worker was present for the decon maintenance, cleaning and organizing the clean room. Negative air
pressure on the floor was -0.030.
I used the stairs to proceed to the 2"'' floor.
2'"' Floor - 18 Asbestos Handlers were present on the floor. Workers were found on scaffolds scraping the
beams and vertical columns of the area 9 - Atrium Area - from the fireproofing, washing scaffolds and
equipment, spraying the fireproofing with amended water. Workers on the floor were sweeping the floor using
equipment equipped with HEPA filters, cleaning the floor from debris, placing into the boxes; plasticizing the
area 10, moving scissor lifts, preparing for fireproofing removal.
Others were replacing the filters of micro trap machines, preparing and loading out boxes.
12 sealed Gaylord boxes were on the floor, sprayed and ready for load out. 22 micro trap machines were
powered on and 5 on stand by. Inspection was done on micro trap tents.
I used the stairs to proceed to the 1^' floor.
1®* Floor - 64 workers were found on the floor. Workers on scaffolds at the area 1 - south side - were scraping
beams and columns from fireproofing. Others were cleaning the floor from debris, placing into the boxes.
Eagle scaffolding workers were erecting platforms inside the north/west shaft. At the north/east side area
workers on two scaffolds were cutting air duct, using equipment equipped with HEPA filters, demolishing and
lifting down the pieces, spraying area with amended water. On north/west side of the floor workers were
plasticizing the critical barriers. Others were cutting metal at the north/east, wrapping beams with poly,
preparing and loading out boxes through the waste decon. 15 Gaylord boxes were on the floor ready for load
out and 15 more boxes were still open. Inspection was done on micro trap machines and tents.
I observed that exhaust duct of the micro trap machine near the tent B-5 was cut off. Foreman Paul on the floor
was advised, and he immediately directed workers to repair the exhaust duct.
I used the stairs to precede to the 3"'* floor.
After following the decontamination procedure I signed the log book and used south hoist to return to the
ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhattan 2=Btonx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)