NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 04/28/09
Floor Zip Borough Block Lot Squad # Badge #
Various_________ 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze_____ F TRU2068MN08 yes
Contractor's Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner's Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY TiTiTiT (212)962-2300
Contact Person Time of Inspection from;
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 1:30 pm to 2:25 pm
I entered the premise at 1:30 pm. LVI schedule informed that activities include;
clear floor, cut ducts, demo walls, ceilings on V'floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal
protective equipment to enter the regulated area on 1'floor Two workers were present
for the decon maintenance, cleaning shower chambers and organizing the clean room.
Negative air pressure was -0.021.
1®' Floor - 75 workers were working inside the work area. Workers were observed on mezzanine
at the west side area, cutting and demolishing the drop ceilings, spraying with amended water,
placing debris into the boxes; Two workers harnessed on scissor lift, were cutting metals from
the wall.
Worker was observed on ladder cutting wires and metal fixtures inside the shaft area. Workers on
scissor lift were breaking down the brick wall in the hallway between two shafts, spraying with
water and placing debris into the boxes.
Other workers were: cutting metal into small pieces at the various locations, placing into the
boxes and spraying; wrapping beams with poly, preparing and loading out sealed and
sprayed boxes through the north side waste decon.
Approximately 70 Gaylord boxes were ready for load out. 35 micro trap machines were powered
on and 5 on stand by. Inspection was done on micro trap tents.
I observed that: 1. Main layer of the exhaust duct, connected to the micro trap at the
South side work area was damaged.
LVI Supervisor was advised, and he immediately directed workers to him to repair exhaust duct.
After following the decontamination procedure I signed the log book and left the decon.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor's Initial
---------------------
Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000131145
NYC-WTC_000182000
OCR can misread numbers and units. Confirm readings against the page image before using them.