Asbestos inspection log, 130 Liberty Street, Feb 2009

Machine-extracted title · confidence 95%

Record of an asbestos inspection conducted at 130 Liberty Street on February 9, 2009, by TRC Environmental Corp.

NYC-WTC_000182035
Page image
Scanned page image, NYC-WTC_000182035
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premises: Inspection Date: 130 Liberty Street 02/09/09 Floor Zip Borough Block Lot Squad# Badge# AO11 Various 10006 1 54 1 1 Inspector Building Type Basis of Inspection Photos Taken N. Patel________ A TRU2068MN08 Yes Contractor’s Name Sample Number LVI Environmental Address City Sample Number 462 Getty Avenue Clifton State Zip Phone Sample Number NJ 07011 (973) 772-3660 Laboratory Name Owner's Name TRC Environmental corp. The Lower Manhattan Development Corp. Address City Address City 1430 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr. /TRC Environmental 8:50 am - 9:50 am 13'^ 4*'’, 2"'’ & T' floor) and 1:25 pm -2:10 pm (5^ floor). On the 3''' floor, I entered to the work area with PPE and met Mr. Geraldo and Mr. Jerry Kadzilla, supervisors. There were 31 people working on the floor. They were demolishing walls and shaft area, boxing debris, cutting pipes with HEPA vacuum attached to the power tool, clearing off floor, preparing Gaylord boxes spraying amended water on the debris in the boxes. Four (4) Gaylord boxes and numerous poly wrapped beams piled on the floor ready to be load out. Negative Air pressure was -0.07.1 used stair B to go to 4"' floor.

On the 4‘'' floor, I met Mr. Victor, foreman. There were 10 people working on the floor. They were clear off floor for demo and cleaning water from floor by vacuum. One micro trap machine was not running and without Air filter. I took photo and told foreman to fix the problem. An inspection was done on micro trap machines and micro trap tents - Air pumps were on. I used stair B to go to 2"“* floor.

On the 2"'’ and P' floor, I met Mr. Jose Jimenez, supervisor. There were 22 people working on the both floors under Mr. Jimenez. They were demolishing walls and bathroom, cleaning out shaft, spraying amended water on the debris, boxing debris and preparing Gaylord boxes. Three (3) Gaylord boxes and numerous poly wrapped beams piled on the floor ready to be load out. 1 found no water near stair B to clean rubber shoes. I told supervisor to put water near stair and he did that. 1 used stair B to go back to 3'^'* floor, proceeds to the decontamination system and showers out.

On the S* floor, I enters to the decontamination system with ATC personal and Mr. Amel Javal of TRC, suits up, dons respirator, enters to the containment and met Mr. Rocco paves, supervisor. There were 26 people working on the floor. They were cleaning work area by vacuuming, checking critical barriers and re-sealing with duct tapes, boxing bags and changing Air filters. Eight (8) Gaylord boxes and number of plastic bags were on the floor ready to be load out. Negative Air pressure was -0.020. Two Micro trap machines were not running and without Air filters. I took photos and told foreman Mr. Raul to fix it. .Also, 1 found few holes in the plastic banier. I show to Mr. Arnel Javal of TRC and also Mr. Paul, foreman and told Foreman to fix it and he did that. 1 proceeded to the decontamination system, decontaminated myself, signed the log book and exited out. My observations were discussed with TRC personal.

NOV# KtSUL I

2 NOV#

NOV# SUPERVISOK

Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code I = Violation Issued 2=No Violation Issued 3=No access 4=Projecl not started (no NOV) 5-PubIic Owned Properly

CITY_DEP_WORBY_CANNATA_SUBP_000131203

NYC-WTC_000182035

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182035Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →