NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 11/19/08
Floor Zip Borough Block Lot Squad # Badge #
Various hE 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU0086MN08 yes
Contractor's Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner's Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
state Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 1:25 pm to 2:30 pm
I arrived at the premise at 1:25 pm. LVI schedule informed that activities include demo shafts,
box debris, scrape fireproofing on 7"’ & 6'^ floors, scrape fireproofing, box debris on 4*’’ floor.
I proceeded to the decon, signed the log book, don appropriate level of personal protective equipment
to enter the regulated area on 6"' floor. Negative air pressure on the floor was 0.046.
Two workers were present for decon maintenance.
I used B stairwell to go to Y'" floor.
7*’’ Floor - 28 workers were working on the floor, cleaning the ceiling of the area 6, spraying with amended
water, washing beams and columns, cleaning the floor from ceiling cleaning. Workers at the area 3
were spraying fireproofing with amended water preparing area for fireproofing removal; carpenters
were working with plywood, putting platforms across the shaft area. Other workers were plasticizing
the floor, wrapping electrical wires with poly, preparing, wrapping and loading out boxes. 14 Gaylord boxes
were ready to be taken out.
Inspection was done on micro trap machines and tents.
20 micro trap machines were powered on and 5 on stand by.
Using B stairs I proceeded to the 6*' floor.
6*” Floor - 20 workers were present on the floor. Workers on South side of the work area were spraying
the fireproofing preparing for removal, wet vacuuming the floor, wrapping wires with poly, picking up
debris and placing into the boxes, wrapping water hose with insulation and poly to prevent from freeze.
Other workers were sealing holes on the floor with poly and duct tape, wrapping electrical cords and wires,
preparing and wrapping boxes, 10 Gaylord boxes were ready for load out.
Inspection was done on micro trap machines and tents.
I used B stairs to proceed to 4“’ floor.
4*" Floor - 28 workers were working on the floor, cleaning the areas at spandular beam, spraying
with amended water, cleaning columns of critical barriers with amended water, dry vacuuming the floor
with the HEPA vacuum equipment, preparing boxes. 10 Gaylord boxes were ready for load out.
20 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents.
I used B stairs to go back to the 6'*’ floor.
After following the decontamination procedure I signed the log book and used north hoist to return to
the ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervis^ Initial
Borough 1=Manhanan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code I = Violation Issued 2=No Violation Issued 3-No access 4=Project not started (no NOV)
5=Public Owned Property