Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 06/20/09 Floor Zip Borough Block Lot Squad # Badge # Various_________ 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU2068MN08 yes Contractor’s Name Sample Number LVI Environmental Address City Sample Number 462 Getty Avenue Clifton State Zip Phone Sample Number NJ 07011 973-772-3660 Third Party Air Monitor Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 212-221-7822 NY 10006 (212)962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. ProJ. Mgr/TRC Environmental 1:10 pm to 2:30 pm

I arrived at the premise at 1:10 pm. LVI schedule informed that activities include: Exterior Fagade removal on s'" and 4“’ floors; fine clean floor, touch up after TRC/ATC visual on 3"“ floor; fine clean floor, touch up after TRC visual; clear floor, scrape fireproofing in shafts, box out debris, loading out boxes to ATC trailer on 1^' floor; demo pipes & ducts, box out debris in basement. North side hoist was repaired and access to the 2"'' floor and up was open. I used north hoist to proceed to the 5'*' floor. 5*^ Floor - 24 Asbestos Handlers were present al the east and south side of the floor; work area was sealed with danger asbestos hazard tape; workers were harnessed on the upper level platforms removing metal panels from the outside of the windows at the south side of the building, wearing double suits, PPA and gloves, using power tools attached to the HEPA vacuum. A large amount of poly wrapped metal pieces exists on the floor. 4 Gaylord boxes were ready to be taken down to the ATC trailer. Using A stairwell I proceeded to the 4^ floor. 4“’ Floor - No activities or personnel observed on the floor; North side area was isolated with red asbestos hazard tape and asbestos notice from west to east side. No wrapped metal pieces or black bags with debris were observed on the floor. 1 used north side hoist to exit the work area and access the 2"“^ floor. I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to enter the regulated area on 2"‘’loor. One worker was present for the decon maintenance, cleaning and organizing the clean room. Negative air pressure on the floor was -0.034. I used “C” stairwell to proceed to the 3'“ floor. 3'“' Floor - 8 Asbestos handlers were found inside the work area in the process of: fine cleaning columns at the east side area using scaffolds; cleaning the floor with wet-dry shop HEPA vacuum. 2 Gaylord boxes were on the floor ready for load out. 20 Micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents. I observed that filters of micro traps were dirty, and air monitoring pump inside the tent B-6 was not operating. Supervisor Geraldo was advised, and he immediately directed workers to replace the filters; inspect and power the pump. Later I contacted Victor Quizphi of TRC to inform him of air monitoring dysfunction. I used “C” stairwell to proceed to the 2"^ floor. 2"'' Floor - 16 Asbestos Handlers were on the floor, cleaning and vacuuming the floor using equipment equipped with HEPA filters; fine cleaning 6 columns at the east side area of the floor using scaffolds; cleaning and drying the floor using fabrics; vacuuming the floor at the shaft area and plasticizing; covering the edges inside and around the shafts. 12 Gaylord boxes were on the floor. Inspection was done on micro trap machines and tents. After following the decontamination procedure I signed the log book, used north hoist to return to the ground floor. Inspection was done on ATC trailer.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s Initial

Borough l=Manliattan 2=Bronx 3=Brooklyn 4=Queens 5=Richinond Building Type A >6 stories B <6 stories C single family D scbool E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000131041

NYC-WTC_000181949

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000181949Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →