NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 06/20/09
Floor Zip Borough Block Lot Squad # Badge #
Various_________ 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
462 Getty Avenue Clifton
State Zip Phone Sample Number
NJ 07011 973-772-3660
Third Party Air Monitor Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 212-221-7822 NY 10006 (212)962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. ProJ. Mgr/TRC Environmental 1:10 pm to 2:30 pm
I arrived at the premise at 1:10 pm. LVI schedule informed that activities include: Exterior Fagade removal on
s'" and 4“’ floors; fine clean floor, touch up after TRC/ATC visual on 3"“ floor; fine clean floor, touch up after
TRC visual; clear floor, scrape fireproofing in shafts, box out debris, loading out boxes to ATC trailer on 1^' floor;
demo pipes & ducts, box out debris in basement.
North side hoist was repaired and access to the 2"'' floor and up was open.
I used north hoist to proceed to the 5'*' floor.
5*^ Floor - 24 Asbestos Handlers were present al the east and south side of the floor; work area was sealed
with danger asbestos hazard tape; workers were harnessed on the upper level platforms removing metal
panels from the outside of the windows at the south side of the building, wearing double suits, PPA and gloves,
using power tools attached to the HEPA vacuum. A large amount of poly wrapped metal pieces exists on the
floor. 4 Gaylord boxes were ready to be taken down to the ATC trailer.
Using A stairwell I proceeded to the 4^ floor.
4“’ Floor - No activities or personnel observed on the floor; North side area was isolated with red asbestos
hazard tape and asbestos notice from west to east side. No wrapped metal pieces or black bags with debris
were observed on the floor.
1 used north side hoist to exit the work area and access the 2"“^ floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to
enter the regulated area on 2"‘’loor.
One worker was present for the decon maintenance, cleaning and organizing the clean room.
Negative air pressure on the floor was -0.034.
I used “C” stairwell to proceed to the 3'“ floor.
3'“' Floor - 8 Asbestos handlers were found inside the work area in the process of: fine cleaning columns at the
east side area using scaffolds; cleaning the floor with wet-dry shop HEPA vacuum. 2 Gaylord boxes were on
the floor ready for load out. 20 Micro trap machines were powered on and 5 on stand by. Inspection was done
on micro trap tents. I observed that filters of micro traps were dirty, and air monitoring pump inside the
tent B-6 was not operating. Supervisor Geraldo was advised, and he immediately directed workers to replace
the filters; inspect and power the pump. Later I contacted Victor Quizphi of TRC to inform him of air monitoring
dysfunction.
I used “C” stairwell to proceed to the 2"^ floor.
2"'' Floor - 16 Asbestos Handlers were on the floor, cleaning and vacuuming the floor using equipment
equipped with HEPA filters; fine cleaning 6 columns at the east side area of the floor using scaffolds; cleaning
and drying the floor using fabrics; vacuuming the floor at the shaft area and plasticizing; covering the edges
inside and around the shafts. 12 Gaylord boxes were on the floor. Inspection was done on micro trap machines
and tents.
After following the decontamination procedure I signed the log book, used north hoist to return to the ground
floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manliattan 2=Bronx 3=Brooklyn 4=Queens 5=Richinond
Building Type A >6 stories B <6 stories C single family D scbool E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000131041
NYC-WTC_000181949
OCR can misread numbers and units. Confirm readings against the page image before using them.