Asbestos inspection log, 130 Liberty Street, May 2009

Machine-extracted title · confidence 95%

Department of Environmental Protection record documenting an asbestos inspection at 130 Liberty Street on May 11, 2009.

NYC-WTC_000181969
Page image
Scanned page image, NYC-WTC_000181969
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 05/11/09 Floor Zip Borough Block Lot Squad # Badge # 1^ Fl__________ 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU2068MN08 yes Contractor's Name Sample Number LVI Environmental Services Inc. Address City Sample Number 462 Gerry Ave Clifton State Zip Phone Sample Number NJ 07011 (973) 772-3660 Third Party Air Monitor Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp, Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 (212) 221-7822 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 5:30 pm to 6:10 pm

I entered the premise at 5:30 pm. LVI schedule informed that activities include: Clear floor, demo & wrap metal, load out on 1’' floor.

I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to enter the regulated area on Vfloor. Two workers were present for the decon maintenance, cleaning shower chambers and organizing the clean room. Negative air pressure was -0.031.

1” Floor - 30 workers were found inside the work area. Two workers on mezzanine at the north/west side work area were cleaning off the floor, picking up debris, metal pieces, placing into the boxes and spraying with amended water.

Two workers were cutting metal into small pieces using equipment equipped with HEPA filter at the north/east side, another worker was spraying with water around the area. A large amount of debris exists on the floor. Workers at the south side area were wrapping beams with poly. Others were replacing filters of micro trap machines, preparing, wrapping and loading out sealed and sprayed boxes through the north side waste decon. 18 Gaylord boxes were ready for load out, 35 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents.

I observed that: 1. Main layer of the exhaust duct, connected to one of the micro traps at the south side work area was broken and needed to be repaired; 2. HEPA vacuum was attached to the electrical tool, but not powered on while worker was cutting metal into the pieces at the south side work area. Supervisor was informed, who then powered on the HEPA vacuum immediately. 3. First main layer of poly inside tent, located at the north/east side area, was detached from the ceiling of the tent and was hanging down.

I met Julio Valero Handler Supervisor inside the work area to advise him to: 1. Conduct emergency repair of exhaust duct, which was repaired immediately; 2. Re-tape poly inside the tent - Supervisor directed two workers to repair the tent in concern; 3. Advice worker to use equipment properly - with HEPA filters attached.

Photos has been taken and attached to the Inspection Report.

After following the decontamination procedure I signed the log book and left the decon. Inspection was done on ATC traIler. NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor's Initial

Borough 1-Manhattan 2=Bronx 3=BrookIyn 4=Queens 5=Richinond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4-Project not started (no NOV) 5=Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000131076

NYC-WTC_000181969

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000181969Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →