Asbestos Inspection Report
Premise No. Inspection Date;
130 Liberty Street 05/12/09
Floor Zip Borough Block .01 Squad # Badge #
V Fl__________ 10006 1 54 I 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor's Name Sample Number
LVI Environmental Services Inc.
Address City Sample Number
462 Gerry Ave Clifton________
State Zip Phone Sample Number
NJ 07011 (973) 772-3660
Third Party Air Monitor Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 (212) 221-7822 NY 10006 (212)962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proi. Mgr/TRC Environmental 10:15 pm to 11:15 pm
I entered the premise at 10:15 pm. LVI schedule informed that activities include:
Clear floor, demo & wrap metal, load out on 1“* floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal
protective equipment to enter the regulated area on 1’‘floor. Two workers were present
for the decon maintenance, organizing the clean room.
Negative air pressure was -0.031.
r‘ Floor - 30 Asbestos Handlers were present at the work area.
I observed two workers harnessed in scissor lift removing metal panels and bricks at the 2"“
vertical beam of the Hallway between shafts at the north/west side work area, spraying with
amended water, picking up debris and placing into the boxes. At the left side of the entrance of
west side personal decon two workers in scissor lift were cutting and demolishing air duct, using
equipment equipped with HEPA filters, spraying around with amended water.
There was a large amount of debris - mixed beams, metal fixtures and conduits - on the
north/west side area of the floor. Two workers were spraying beams and wrapping with poly.
Workers were cutting metal into small pieces using equipment equipped with HEPA filter
at the north/west and south side work area, spraying with amended water.
Others were preparing, wrapping and loading out sealed and sprayed boxes through
the north side waste decon.
lOGaylord boxes were ready for load out. 35 micro trap machines were powered on and
5 on stand by. Inspection was done on micro trap tents.
I observed that: 1. Exhaust duct of one of the micro trap machines at the north side area was
partially detached and needed to be re-taped. 2. Electrical cables were hanging down at the
south side work area.
Handler Supervisor Julio Valero was advised, and tree workers performed emergency repair of
the exhaust duct and elevation of the electrical cables.
After following the decontamination procedure I signed the log book and left the decon.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property