NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 03/11/09
Floor Zip Borough Block Lot Squad # Badge #
Various_________ 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor's Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 ;2121962-2300
Contact Person Time of Inspection from:
Amel Javal, Sr. Proj. Mgr/TRC Environmental 5:45 pm to 6:45 pm
I arrived at the premise at 6:00 pm. LVI schedule informed that activities include:
clear floor, cut ducts, demo walls, ceilings on V’ floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal
protective equipment to enter the regulated area on Y'floor. Three workers were present
for the decon maintenance, cleaning the shower chambers and organizing the clean room.
Manometer reading of the negative air pressure was -0.032.
V* Floor - 56 workers were present inside the work area. Workers were still clearing the
shafts from debris, spraying with amended water, placing into the boxes.
Three workers on mezzanine inside the engine room were cutting and removing conduit.
At the west side vestibule workers on scissor lift were breaking down the hard drop
ceiling, using hammer and electrical power tool, attached to the HEPA vacuum.
I observed four workers harnessed on two scissor lifts, breaking plaster ceiling into the
pieces on the east side area, bringing down pieces from ceiling to the floor; one worker was
spraying the area with amended water.
Workers were obsen/ed at the north side vestibule cutting metal fixtures from the ceiling. ,
Other workers were: cutting metal into small pieces at the various locations,
placing into the boxes and spraying with amended water; preparing boxes, wrapping beams
with poly, loading out sealed and sprayed boxes through the north side waste decon.
A large amount of debris and poly wrapped beams still exists on the floor.
I observed dirty filters of micro trap machines, and two light bulbs with damaged cages.
Foreman was advised, and he directed worker to replace the filters, then he contacted electricians
to inform them that light protections needed to be replaced.
56 Gaylord boxes were on the floor ready to be taken out. 35 micro trap machines were
powered on and 5 on stand by. Inspection was done on micro trap tents.
After following the decontamination procedure I signed the log book and left the decon.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2_______________
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Riclimond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2-No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY DEP WORBY CANNATA SUBP_000131147
NYC-WTC_000182002
OCR can misread numbers and units. Confirm readings against the page image before using them.