NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 55/No folder label
Document / 274 pages

EPA work plan review, 133-135 and 21-23 buildings, August 2005

Machine-extracted title · confidence 75%

EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.

NYC-WTC_000134871–000135144
Page image
Scanned page image, NYC-WTC_000135036
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part III — Health & Safety Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 — Rev 1, August 11, 2005 2. Floor Coverings 3. Sheetrock & Joint Compound 4. Pipe Insulation 5. Electrical Wire Insulation 6. Roofing Products 7. Brick Mortar 8. Window Caulk & Glazing

Based on the currently recommended sampling and analytical procedures, Airtek recommends that additional sampling is necessary, in order to determine the asbestos content of building materials. 3.0 SUMMARY OF AIRTEK ENVIRONMENTAL'S INSPECTION RESULTS:

The asbestos inspection was conducted on 5/26/05 & 5/27/05 and involved a thorough visual examination of all areas and sampling of suspect materials that would be impacted during the proposed demolition.

Airtek Laboratory analysis confirmed the presence of asbestos in the amount greater than 1% within the samples collected from the following material: Bulkhead Tar

Airtek laboratory analysis determined the samples collected from the following materials to contain less then one percent (<1%) asbestos.

1. Textured Ceiling 2. Carpet Mastic 3. Ceiling Tiles 4. Floor Tile Grout 5. Tar on HVAC Ducts 6. Wall Tile Grout 7. Wall Tile Glue 8. 12" x 12" Floor Tiles & Mastic 9. Electric Wire Insulation 10. Sheetrock & Joint Compound

4.0 CONCLUSIONS AND RECOMMENDATIONS: Asbestos-containing materials, which will be affected by the scope of work, have been positively identified at various locations throughout the building(s). Proper asbestos abatement procedures shall be implemented prior to the commencement of demolition work. All asbestos abatement work shall be performed in accordance with all applicable Federal, State and Local rules and regulations. The abatement project shall be filed with agencies having jurisdiction over this project, such as USEPA, NYSDOL and NYCDEP. all

A licensed abatement contractor must perform the removal of all friable and non-friable ACM. Airtek believes that the implementation of these recommendations will serve to best protect human health and the environment. To assure that the removal of the aforementioned ACM is properly and effectively carried out, the following recommendations are proposed by Airtek: A. Develop and implement a schedule that outlines the time frame for removal of ACM.

Fa

NYC-WTC 000135036

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135036Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →