Part II- Environmental Community Monitoring Plan
133-135 Greenwich & 21-23 Thames Streets
Airtek Project 05-0701 — Rev 1 August 11, 2005
Extensive effort and cost has been invested in working with the NYC
Department of Education to provide engineering controls and testing
support to protect the educational facilities at 100 and 90 Trinity Place.
Detailed information on these efforts is included in Attachment II to Part I
of this submittal — "Work Plan."
1.3.2 125 Greenwich Street
Specific measures are planned to monitor the impact of the project on the
125 Greenwich Street building. One of the Environmental Community Air
Monitoring stations specified in this document (school auditorium roof
station) is directly adjacent to this building (within 20'). In addition, the
Environmental Consultant will conduct Abatement Phase work area
monitoring continuously during abatement phase work shifts between the
project site and the 125 Greenwich Street building.
1.3.3 Bldg. South of Thames Street
This building, across Thames Street from the Project Site, will be
separated from the project site by two Environmental Community Air
Monitoring stations. In addition, during the Abatement Phase, extensive
work area monitoring will be conducted on Thames Street.
1.4 Environmental Sampling and Analytical Methodologies
Sampling and analytical methodologies utilized for this Project, will comply with
published protocols from EPA and/or National Institute of Occupational Safety
and Health ("NIOSH"). Where appropriate other published standards may be
substituted and project-specific adjustments to protocols may be made. Generally,
sampling will be conducted once every 24-hour work period, except or asbestos
(TEM samples), which will be taken for the duration of every work shift and once
a day during non-work days during the abatement phase. Real-time particulate
monitoring will be on a continuous basis. Instantaneous mercury readings will be
obtained to evaluate the air quality around the work site at multiple locations each
work day.
2.0 Visible emissions
2.1 Abatement Phase
At the commencement of each work shift, the Environmental Site Hygienist will
conduct a thorough inspection of all engineering control systems including
containment barriers, and negative air control systems, and exterior. If any visible
emission is noted on the exterior of the work area, all work will be stopped and
not restarted until an evaluation of engineering controls has identified and
corrected the cause of the emission. The evaluation may include, but is not limited