Asbestos Abatement

b) Remove the material using hand tools such as scrapers or putty knives. Wire-mesh or wood lathe reinforcing, when present, shall be cut into manageable pieces and disposed of as ACM.

c) Remove any residual material from the substrate using wet cleaning methods and nylon-bristled hand brushes.

d) Place the removal material immediately into a properly labeled 6- mil polyethylene bag. All material shall be properly containerized and decontaminated prior to removal from the Work Area.

e) Following the completion of removal of insulation, all visible residue shall be removed from the substrate

3. Following Removal of ACM utilizing Full Containment Procedures:

a) First Cleaning:

(1) Remove any visible accumulation of asbestos material and debris. HEPA-vacuuming and wet cleaning shall be performed on all surfaces inside the Work Area. All sealed drums, plastic bags, and equipment used in the Work Area shall be removed from the Work Area.

(2) Upon request of the Contractor, the Testing Eaboratory will perform a visual inspection. Evidence of asbestos contamination identified during the inspection will necessitate further cleaning as heretofore specified.

(3) Remove first layer of plastic sheathing inside the Work Area. The isolation barriers and decontamination facility shall remain in place and be utilized.

b) Second Cleaning:

(1) After the first cleaning, the Work Area shall be vacated for twelve hours to allow fibers to settle.

(2) All objects and surfaces in the Work Area shall be HEPA - vacuumed and wet cleaned for a second cleaning.

(3) A thin coat of lockdown encapsulant shall be applied to all plastic covered surfaces in the Work Area.

(4) When the encapsulant is dry, second layer of polyethylene sheeting on the walls, ceiling and floors shall be removed.

CAPITAL PROJECT NUMBER PO79201K 02081-76 100: CONTRACT DOCUMENTS REV. May 3,2000 - 76 -100% CONTRACT DOCUMENTS REV. 0: DATE

CITY_21MC100_006631325

NYC-WTC_000416837

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000416837Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

Asbestos, NY DOL reference

NYC-WTC_000441450

Asbestos standards reference page from NY Department of Labor materials.

Similar indexed content

Compare copies and versions →