Asbestos Abatement
C. Removal of ACM Utilizing Pull Containment Procedures shall be as follows:
1. Preparation Procedures:
a) Ensure that the Testing Laboratory has performed area monitoring
and established a background count prior to the preparatory
operations for each removal area, as applicable.
b) Shut down, isolate, and lock out or tag heating, ventilating, and air
conditioning (HVAC) systems which serve or which pass through
the Work Area. Vents within the Work Area and seams in HVAC
components shall be sealed with tape and two layers of
polyethylene sheeting. Eilters in HVAC systems shall be removed
and treated as asbestos-contaminated waste.
c) Shut down, disconnect, and lock out or tag all electric power to the
Work Area so that there is no possibility of its reactivation until
after clearance testing of the Work Area.
d) Provide and install decontamination enclosure systems in
accordance with Articles 3.01 and 3.02 of this Section.
e) Remove ACM that may disturbed by the erection of partitions
using tent procedures and wet removal methods Removal shall be
limited to a one-foot wide strip running the length/height of the
partition.
f) Pre-clean and remove moveable objects from the Work Area. Pre
cleaning shall be accomplished using HEPA-vacuum and wet
cleaning techniques. Store moveable objects at a location
determined by the City.
g) Protect carpeting that will remain in the Work Area.
(1) Pre-clean carpeting utilizing wet-cleaning techniques.
(2) Install a minimum of two layers of 6-mil reinforced
polyethylene sheeting over carpeting.
(3) Place a rigid flooring material, minimum thickness of 3/8-
inch, over polyethylene sheeting.
h) Pre-clean all fixed objects to remain within the Work Area using
HEPA-vacuum and wet-cleaning techniques.
CAPITAL PROJECT NUMBER PO79201K 02081-72
100: CONTRACT DOCUMENTS REV. May 3,2000
- 72 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631321
NYC-WTC_000416833