ALLOWANCE FOR INCIDENTAL ASBESTOS ABATEMENT

Contractors who may be brought upon any site of the work of this Contract. This paragraph applies to those areas outside the regulated Work Area as defined by Title 15, Chapter I of RCNY.

1.12 LOG

A. The Contractor shall provide a permanently Bound logbook of minimum 8-1/2" X 11" size. Log book shall contain on title page the project name, name, address and phone number of Agency Representative; name, address and phone number of Contractor; name, address and phone number of Contractor's and City's air testing entity; emergency phone numbers including, but not limited to local Fire/Rescue Department. Log book shall contain a list of personnel approved for entiy into the Work Area

B. All entries into the log sill be made in non-washable, permanent ink and such pen shall be strung to or otherwise attached to the log to prevent removal from the log-in area. Under no circumstance shall pencil entries be permitted.

Upon completion of the job and as a condition of its acceptance, submit the job logbook containing day-to-day record of personnel entering the Work Area, and any significant event occurring during the abatement of the project. Daily log entries shall be countersigned by the Resident Engineer every day.

1.13 PROTECTION OF FURNITURE AND EQUIPMENT A. Cover all furniture and equipment that cannot be removed from Work Areas. Movable furniture and equipment will be removed from Work Areas by the Contractor prior to start of work. At the conclusion of the work (after fmal air testing), the Contractor will remove all plastic covering on walls, floors, furniture, equipment and reinstall furniture and equipment. He shall remove and store all sheaths, curtains and drapes, and reinstall same following final clean up.

1.14 UTILITIES A. General:

All temporary facilities shall be subject to the approval of the Commissioner. Prior to starting work at any site, locations and/or sketches (if required) of temporary facilities must be submitted to the Resident Engineer for the required approval.

B. Water:

The Department of Design and Construction will furnish all water needed for construction, at no cost to the Contractor in buildings under their jurisdiction. However, it is the responsibility of the Contractor to ensure that hot water is provided for showering in the decontamination unit. The Contractor shall furnish.

CAPITAL PROJECT NUMBER XXXXX 01020-1 02 100% CONTRACT DOCUMENTS REV. 0: DATE

CITY_21MC100_006631351

NYC-WTC_000416863

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000416863Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

Asbestos, NY DOL reference

NYC-WTC_000441450

Asbestos standards reference page from NY Department of Labor materials.

Similar indexed content

Compare copies and versions →