NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 03/03/09
Floor Zip Borough Block Lot Squad # Badge #
Various 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gagnidze_____ F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner's Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 8:35 am to 10:10 am
I arrived at the premise at 8:35 am. LVI schedule informed that activities include: demo in shafts, demo walls,
clear off floor. Eagle temp platforms in shaft on S"" floor, demo walls, clear off floor, scrape Mezzanine
fireproofing,. Eagle erect platforms various locations on 2"'* floor, clear floor, cut ducts, demo walls, ceilings on
1floor. Negative air manometer reading was 0.031.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to
enter the regulated area on 3'‘’floor. Two workers were present for the decon maintenance, cleaning the shower
chamber and organizing the clean room.
3'" Floor - 32 workers were present on the floor. Workers on scissor lifts were performing demolition of
sheetrock wall between the two shafts, spraying with amended water, two others picking up debris and placing
into the boxes. Workers on scissor lifts at the various locations of the work area were cutting metal fixtures from
the ceiling. Carpenters working with plywood, preparing to erect the platforms around the shaft, I observed two
workers plasticizing the hole at the south side critical barrier. A large amount of debris and poly wrapped beams
were on the floor. 5 Gaylord boxes were ready to be taken out. Inspection was done on micro trap machines
and tents. I observed that one micro trap was not running and exhaust duct of the other machine was detached.
I advised the Handler Supervisor, and he immediately directed workers to repair the damages.
I used B stairwell to proceed to the 2™* floor.
2"“' Floor - 56 workers were found inside the work area, cutting metal fixtures from the ceiling at the various
locations, plasticizing electrical room. Workers on mezzanine located between the 2"“ and V floors were
scraping the fireproofing, spraying around the area and cleaning floor from debris. Others were cutting metal
using tools attached to the HEPA vacuum, wrapping beams with poly, preparing boxes. 15 Gaylord boxes were
on the floor sealed, sprayed and ready for load out. 35 micro trap machines were powered on and 5 on stand
by. Inspection was done on micro trap tents.
I used B stairwell to proceed to the l” floor.
V' Floor - 81 workers on the floor were: demolishing brick wall and spraying with amended water; workers on ,
scissor lift were taking down hard concrete drop ceiling, removing black metal panels from the columns at the ;
south side of the work area, clearing shafts, placing debris into the boxes and spraying with amended water,
cutting metal at the various locations into the pieces, preparing, wrapping and loading out boxes through the
waste decon. A large amount of debris and poly wrapped beams exists on the floor. 12 Gaylord boxes were on
the floor ready to be taken out. Inspection was done on micro trap machines and tents.
I used B stairwell to go back to the 3’''floor.
After following the decontamination procedure I signed the log book and used north hoist to return to the
ground floor.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough I “Manhattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property