NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 06/06/09
Floor Zip Borough Block Lot Squad # Badge #
Various_________ 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M Gagnidze F TRU2068IV1N08 yes
Contractor’s Name Sample Number
LVI Environmental
Address City Sample Number
State Zip Phone Sample Number
Laboratory Name Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY tooia NY 10006 (212)962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proi. Mqr/TRC Environmental 7:00 pm to 7:40 pm
I arrived at the premise at 7:00 pm. LVI schedule informed that activities include; clear floor,
scrape fireproofing, demo, load out on 1®' floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal protective
equipment to enter the regulated area on V*floor.
Two workers were present for the decon maintenance, cleaning and organizing the clean room.
Negative air pressure on the floor was -0.034.
1** Floor - 30 workers were present on the floor. Workers were found on north/west side mezzanine
near west side personal decon scraping the ceilings, vertical and horizontal beams,
spraying with amended water to wash and clean, picking up fireproofing debris, using metal shovels,
placing into the boxes.
Two asbestos handlers on mezzanine at the right side of the personal decon and one worker on
scissor lift were demolishing the wall, breaking cinder blocks, spraying with amended water.
Other workers were re-plasticizing the critical barriers at the west and east shaft areas,
cutting metal into the pieces, spraying with water, preparing and loading out boxes through
the waste decon. 12 Gaylord boxes were on the floor ready for load out. 40 micro trap machine
were on and 5 on stand by. Inspection was done on micro trap tents.
Using entrance from the first floor I proceeded to the basement.
Bsmt - No activities or personnel observed on site. 10 micro trap machines were powered on.
I went back to the V floor.
After following the decontamination procedure I exited the work area.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor's Initial
4^'
Borough l=Manhattan 2=Bronx 3=Brooldyn 4=Queens 5=Richmoiid
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
C ITY_D EP_WO RBY_C AN NAT A SU B POO0131089
NYC-WTC_000181973
OCR can misread numbers and units. Confirm readings against the page image before using them.