Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 05/01/09 Floor Zip Borough Block Lot Squad # Badge # 1’* Fl 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU2068MN08 yes Contractor’s Name Sample Number LVI Environmental Services Inc. Address City Sample Number 462 Gerry Ave Clifton State Zip Phone Sample Number NJ 07011 (973) 772-3660 Third Party Air Monitor Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 (212)221-7822 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 8:55 pm to 10:00 pm

I entered the premise at 8:55 am. LVI schedule informed that activities include: clear floor, cut ducts, demo walls, ceilings on 1®' floor.

I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to enter the regulated area on Vfloor. Two workers were present for the decon maintenance, organizing the clean room. Negative air pressure was -0.026.

V Floor - 75 workers were found inside the V floor work area. Eagle scaffolding workers at the north/west side extended area were erecting scaffolds, preparing the area to cut the vertical beams and metal fixtures from the brick wall.

Workers on mezzanines of the west side area were clearing off floor, picking up debris, placing into the boxes and spraying with amended water, preparing the area for air duct removal.

Eagle scaffolding workers were at the north side shaft area erecting the scaffolds. Workers were observed on scaffolds at the north vestibule removing insulation of the airducts, spraying with amended water during removal.

Other workers were: cutting metal into the pieces at the south side, spraying the area with amended water; preparing boxes, wrapping beams with poly, loading out sealed and sprayed boxes through the north side waste decon. Approximately 30 Gaylord boxes were ready for load out. 35 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents.

After following the decontamination procedure I signed the log book and left the decon. Inspection was done on ATC trailer.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2____________________ NOV# Infraction Infraction Infraction Supervisor’s Initial^^^^,

Borough 1 “Manhattan 2-Bronx 3-Brooklyn 4=Queens 5=RicluTiond BuildmgType A >6 stories B <6 stones C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=PubIic Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000131070

NYC-WTC_000181965

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000181965Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →