NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 05/12/09
Floor Zip Borough Block Lot Squad # Badge #
1^ Fl__________ 10006 1 54 1 1 A062
Inspector I Building Type Basis of Inspection Photos Taken
M.Gagnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental Services Inc.
Address City Sample Number
462 Gerry Ave Clifton
State Zip Phone Sample Number
NJ 07011 (973) 772-3660
Third Party Air Monitor Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 (212) 221-7822 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proi. Mgr/TRC Environmental 6:50 pm to 7:30 pm
I entered the premise at 6:50 pm. LVI schedule informed that activities include:
Clear floor, demo & wrap metal, load out on 1 floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal
protective equipment to enter the regulated area on 1 “floor. Two workers were present
for the decon maintenance, organizing the clean room.
Negative air pressure was -0.026.
1’‘ Floor - 30 Asbestos Handlers were working on the floor in shifts.
There was a large amount of debris - mixed beams, metal fixtures and conduits -
on the north/west side area of the floor. Two workers were spraying beams and wrapping
with poly.
Workers at the north side hallway were jack hammering the floor, breaking the concrete to
make the floor even, spraying debris and placing into the boxes.
At the north/east side of the hallway two workers harnessed in scissor lift were demolishing
brick wall - upper part of metal and glass partition of former “Shoe Repair Shop",
spraying the area with amended water.
On the north side mezzanine workers were removing metal panel from the wall.
Workers were cutting metal into small pieces using equipment equipped with HEPA filter
at the north/west and south side work area, spraying with amended water.
Others were replacing filters of micro trap machines, preparing, wrapping and loading
out sealed and sprayed boxes through the north side waste decon.
12Gaylord boxes were ready for load out. 35 micro trap machines were powered on and
5 on stand by. Inspection was done on micro trap tents.
After following the decontamination procedure I signed the log book and left the decon.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manliattan 2=Bronx 3=Brooklyn 4=Queens 5=Rjctimoiid
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property
CITY_DEP_WORBY_CANNATA_SUBP_000131074