Asbestos inspection log, 130 Liberty Street, May 14, 2009

Machine-extracted title · confidence 95%

Record of an asbestos inspection conducted at 130 Liberty Street on May 14, 2009, by LVI Environmental Services Inc.

NYC-WTC_000181989
Page image
Scanned page image, NYC-WTC_000181989
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 05/14/09 Floor Zip Borough Block Lot Squad # Badge# 1“ Fl 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze F TRU20B8MN08 yes Contractor’s Name Sample Number LVI Environmental Services Inc. Address City Sample Number 462 Gerry Ave Clifton State Zip Phone Sample Number NJ 07011 (973) 772-3660 Third Party Air Monitor Owner's Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 (212)221-7822 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 5:20 pm to 6:20 pm

I entered the premise at 5:20 pm. LVI schedule informed that activities include: Clear floor, demo & wrap metal, load out on 1®' floor.

I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to enter the regulated area on 1'floor. Two workers were present for the decon maintenance, organizing the clean room. Negative air pressure was -0. 024.

1" Floor - 34 Asbestos Handlers were inside the work area. Workers were covering holes and pipes with foam and plasticizing the floor with poly near the entrance of east side personal decon. Workers at the east side vestibule were cleaning floor from debris, sweeping with HEPA vacuum. At the north side vestibule three workers were inside the escalator shaft, cleaning the area and plasticizing with poly. At the south/east side of the area near former mechanical room workers were removing metal panels to fill up the holes and trenches with foam, then to cover with poly.

Others were plasticizing the edges, hallways at the south side area, preparing, wrapping and loading out sealed and sprayed boxes through the north side waste decon. 13Gaylord boxes were ready for load out. 35 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents.

After following the decontamination procedure I signed the log book and left the decon. Inspection was done on ATC trailer.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s Initial

Borough 1-Manhattan 2=Bronx 3=Brook]yn 4=Queens 5=Ricliniond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=Public Owned Property

C ITY_D EP_WO RBY_C AN NAT A SU B POO0131108

NYC-WTC_000181989

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000181989Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →