NYC 9/11 Public Portal Document
Asbestos Inspection Report
Premise No. Inspection Date:
130 Liberty Street 05/26/09
Floor Zip Borough Block Lot Squad # Badge #
V' Fl 10006 1 54 1 1 A062
Inspector Building Type Basis of Inspection Photos Taken
M.Gaqnidze F TRU2068MN08 yes
Contractor’s Name Sample Number
LVI Environmental Services Inc.
Address City Sample Number
462 Gerry Ave Clifton
State Zip Phone Sample Number
NJ 07011 (973) 772-3660
Third Party Air Monitor Owner’s Name
TRC Environmental Corp The Lower Manhattan Development Corp.
Address City Address City
1340 Broadway New York One Liberty Plaza New York
State Zip Phone State Zip Phone
NY 10018 (212)221-7822 NY 10006 (212) 962-2300
Contact Person Time of Inspection from:
Arnel Javal, Sr. Proj. Mgr/TRC Environmental 6:25 pm to 7:20 pm
I entered the premise at 6:25 pm. LVI schedule informed that activities include:
Clear floor, scrape fireproofing, load out on V' floor.
I proceeded to the decon, signed the log book, don the appropriate level of personal
protective equipment to enter the regulated area on Vfloor. Three workers were present
for the decon maintenance, cleaning the shower chambers and organizing the clean room.
Negative air pressure was -0.050.
V' Floor - 33 Asbestos Handlers were inside the work area.
Workers harnessed in three scissor lifts at the area 4 were scraping fireproofing from ceiling and
beams, spraying with amended water north/east side of the work area; washing and fine cleaning
ceiling, vertical and horizontal beams, plastic of the wall at the north side area; other workers were
picking up debris from the floor using metal shovels, placing into the boxes, cleaning the plastic on
the floor. Workers at the north side waste decon were dry cleaning the floor using HEPA vacuum.
At the north/west side corner two workers on scaffolds were cutting and removing the metal
panels from the beam using equipment equipped with HEPA filters, spraying the area with
amended water.
Others were cutting metal into the pieces at the west side vestibule near former mechanical room,
placing into the boxes and spraying; preparing, wrapping and loading out sealed and sprayed
boxes through the north side waste decon.
11 Gaylord boxes were ready for load out and 8 boxes still open. 35 micro trap machines were
powered on and 5 on stand by. Inspection was done on micro trap tents.
After following the decontamination procedure I signed the log book and left the decon.
Inspection was done on ATC trailer.
NOV# Infraction Infraction Infraction Infraction
NOV# Infraction Infraction Infraction Result Code
2
NOV# Infraction Infraction Infraction Supervisor’s Initial
Borough l=Manliattan 2=Bronx 3=Brooklyn 4=Queens 5=Richmond
Building Type A >6 stories B <6 stories C single family D school E hospital F public owned
Result Code 1 = Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV)
5=Public Owned Property