Worid Trade Center Emergency Project Environmental, Safety, and Health Plan Draft - Revision A 30 September 2001
• Operators of over-the-road vehicles such as haul trucks and water trucks must possess a valid commercial driver’s license (CDL) if a CDL is normally required when operating such vehicles on public roads. • Eating, drinking, smoking and use of personal cellular telephones and radios are prohibited when operating construction equipment in active work areas. • Construction equipment operators shall have the experience, skills and knowledge to safely operate the equipment to be used. • Construction equipment used for demolition or materials handling shall be equipped with demolition cage, wire screen, or equivalent structures to prevent materials or debris from breaking cab windows where the potential for window breakage hazards exists. Construction equipment shall be equipped with operable audible backup indicators. • Personnel in areas in which heavy equipment is being operated shall wear high visibility (e.g., orange) traffic safety vests and make eye contact with the operator before approaching. • Employees shall only be transported in vehicles meeting the requirements of 49 CFR 571. Vehicles used to transport personnel shall have seats firmly secured and adequate for the number of employees to be carried. Seat belts and anchorages meeting the requirements of 49 CFR 571 shall be installed in all motor vehicles.
3.7 WORKING FROM ELEVATED SURFACES/STRUCTURES
On hundred percent (100%) fall protection in accordance with 29 CFR 1926 Subpart M is required. Personnel may be required to work on elevated structures to access Ground Zero areas and peripheral locations to inspect and/or conduct analyses of damaged structures. Others may be required to work at elevated heights during demolition of certain areas within a work Zone. These elevated structures may include ladders, scaffolding, scissors lifts, elevating/rotating boom lifts (aerial work platforms), man baskets, etc. Also, cleanup work may require personnel to access and survey roof areas and other elevated structures of buildings adjacent to the WTC Complex. These areas may not offer tested tie-off locations for fall protection. There are also a number of obstacles located on the various roof levels (e.g., air handlers, compressors, piping, vent stacks, etc.).
Aerial lifts shall be operated in accordance with the requirements of 29 CFR 1926.453 and manufacturers recommendations. All aerial lifts shall be inspected prior to use. Documentation of inspections shall be available upon request.
3.8 ELECTRICAL SAFETY
All electrical equipment including extension cords, generators, electrical power tools, light plants, temporary lighting, etc. shall be used, maintained, and inspected in accordance with 29 CFR 1926 Subpart K.
In addition, all construction zone 110 volt outlets shall be equipped with GFCI protection.
41
NYC-WTC_000164711
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000165900
Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.
15 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164098
Distribution of materials provided at January 15, 2002 WTC contractor health and safety meeting.
24 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000127738
Health and safety plan for Phase I deconstruction at 133-135 Greenwich Street and 21-23 Thames Street dated June 8, 2005.
17 shared non-person entities · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142247
Generic DEP form from Box 06 with illegible content regarding environmental services.
11 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
24 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
33 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
18 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
33 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153468
Page containing illegible text and a document identifier for the EPA Inspector General series.
13 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095781
Part III of a permit application dated January 10, 2006 regarding health and safety for remediation at 30 West Street.
15 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
15 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153096
Interagency memo circulating EPA revisions for NESHAP and related programs with request for legal and agency comments.
14 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000124224
Letter from Brookfield requesting approval to open 1 Liberty Plaza for occupancy on October 22, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000141585
Map showing the condition of buildings at the World Trade Center site as of September 21, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Cited alongside this record in an Ask answer