NYC-WTC_000165900
Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.
15 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗Draft document titled World Trade Center Emergency Safety and Health Plan dated September 30, 2001.
NYC-WTC_000164671–000164730
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
World Trade Center Emergency Project Environmental, Safety, and Health Plan Draft - Revision A 30 September 2001
3.4 DEMOLITION SAFETY
All demolition operations (including use of explosives) shall at a minimum meet the requirements of 29 CFR 1926 Subpart T.
Contractors shall develop a demolition plan, for review and approval by the WTC Emergency site ES&H director or designee, that addresses the specific hazards and work steps of specific demolition projects. The plan shall be reviewed and approved prior to the start of the demolition of any existing structures.
3.5 CRANE AND HOISTING OPERATIONS
Crane operations shall be conducted in accordance with 29 CFR 1926.550, Cranes and Derricks. Rigging of loads being lifted by cranes shall comply with the requirements of 29 CFR 1926.251, Rigging Equipment for Material Handling. Contractors shall develop a lift plan for each lift that meets any of the following conditions:
• The weight of the lift exceeds 75 percent of the crane’s rated capacity in the configuration that will be used during the lift • Lifts for which the path of travel is out of the operator’s view • Lifts made with more than one piece of lifting equipment • Lifts involving non-routine or difficult rigging arrangements • Hoisting of personnel with a crane or derrick shall be done in accordance with 29 CFR 1926.550 (g) • Lifts involving high value items where damage would result in an unacceptable financial or production loss • Any lift which the lifting equipment operator believes should be considered critical
If adverse weather conditions affect the safe operations of cranes, all hoisting and rigging operations shall cease.
3.6 CONSTRUCTION EQUIPMENT SAFETY
Use and operation of construction equipment such as motorized vehicles, heavy equipment, water trucks, and haul trucks (excluding passenger vehicles and pickup trucks) shall meet the following requirements:
• On-site equipment shall meet the requirements of all relevant OSHA standards. • Equipment will be inspected by the Contractor designee upon arrival and prior to use. Deficiencies found shall be corrected before use. • Operators shall complete inspections on all construction equipment prior to use each day to ensure that parts, accessories, and equipment are in safe operating condition and free of apparent damage.
40
NYC-WTC_000164710
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000165900
Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.
15 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164098
Distribution of materials provided at January 15, 2002 WTC contractor health and safety meeting.
24 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000127738
Health and safety plan for Phase I deconstruction at 133-135 Greenwich Street and 21-23 Thames Street dated June 8, 2005.
17 shared non-person entities · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142247
Generic DEP form from Box 06 with illegible content regarding environmental services.
11 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
24 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
33 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149199
Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.
18 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
33 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153468
Page containing illegible text and a document identifier for the EPA Inspector General series.
13 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095781
Part III of a permit application dated January 10, 2006 regarding health and safety for remediation at 30 West Street.
15 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
15 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153096
Interagency memo circulating EPA revisions for NESHAP and related programs with request for legal and agency comments.
14 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000124224
Letter from Brookfield requesting approval to open 1 Liberty Plaza for occupancy on October 22, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000141585
Map showing the condition of buildings at the World Trade Center site as of September 21, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Cited alongside this record in an Ask answer