Mr Rajappan Radhakrishnan — NYC DEP 133-135 Greenwich Street Variance Request Airtek Project 05-0701— August 11, 2005

We proposed to use Attachment FR - Procedures for use of Foam or Similar Viscous Liquid in Removal of Asbestos Containing Roofing (ACRM) in New York City

In-place ACM has been identified as follows:

1. Bulkhead Tar —10 sf 2. Roof Flashing — 35 sf

These materials will be abated last in the decontamination sequence. For detailed information on the asbestos survey conducted, please refer to the Airtek Asbestos Survey Report dated May 31, 2005 (Attached).

Utilities - General:

Utility service is currently cut off to the building. All electricity and water required for the work will be drawn from sources outside the building.

Project Monitoring:

Project Monitoring: Throughout the decontamination activities, project air monitoring will be conducted in addition to the Perimeter Monitoring described above. Project Monitoring will be conducted in strict accordance with RCNY Title 15 Chapter 1, Section 1-41 to 1-45, with the exception that all sample analyses will be by TEM.

Clearance Testing: Aggressive area clearance testing for asbestos will be conducted for all work areas by TEM. Aggressive clearance testing for metals will be conducted by NIOSH 7300.

Clearance Criteria:

Clearance testing for asbestos will be acceptable when all samples for a given work area meet the 70 structures per square millimeter TEM standard. Clearance testing for metals will be acceptable when all samples meet the following criteria:

Antimony 250 ug/m3 Barium 250 ug/m3 Beryllium 1.0 ug/m3 Cadmium 5.0 ug/m3 Chromium (III) 250 ug/m3 Copper 500 ug/m3 Lead 25 ug/m3 Manganese 100 ug/m3 Mercury 12.5 ug/m3 Nickel 50 ug/m3 Zinc 1,000 ug/m3

NYC-WTC 000134904

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000134904Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →