EPA work plan review, 133-135 and 21-23 buildings, August 2005

Machine-extracted title · confidence 75%

EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.

NYC-WTC_000134871–000135144
Page image
Scanned page image, NYC-WTC_000135081
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part III — Health & Safety Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 —Rev 1, August 11, 2005 LABORATORY RESULTS

Homogeneous Sample PLM PLM-NOB TEM-NOB Location Material Area # Results A 1 5th Fl Roof Flashing - 5.2% Ch - A 2 5th FI Roof Flashing - NA/PS - A 3 5 FI Roof Flashing - NA/PS - B 4 5tT FI Roof Bulkhead Tar - 4.8% Ch - B 5 5 FI Roof Bulkhead Tar - NA/PS - B 6 5th FI Roof Bulkhead Tar - NA/PS - C 7 5 Fl Roof Roof Material - 4.5% Ch - C 8 5th FI Roof Roof Material - NA/PS - C 9 5 FI Roof Roof Material - NA/PS - D 10 5th FI Roof Brick Mortar ND - - D 11 5th FI Roof Brick Mortar ND - D 12 5 FI Roof Brick Mortar ND - - E 13 5th FI Roof Coping Stone Mortar ND - - E 14 5th FI Roof Coping Stone Mortar ND - - E 15 5th Fl Roof Coping Stone Mortar ND - - F 16 5th FI Roof Coping Stone Caulk - 2.2% Ch - F 17 5th Fl Roof Coping Stone Caulk - NA/PS - F 18 5th Fl Roof Coping Stone Caulk - NA/PS - G 19 5th Floor Window Caulk - 2.2% Ch - G 20 3 Floor Window Caulk - NA/PS - G 21 2" Floor Window Caulk - NA/PS - <1.0°~ Anth H 22 5'" Floor Window Glazing - Inconclusive Trace Ch <1.0% Anth H 23 3`d Floor Window Glazing - Inconclusive Trace Ch <1.0% Anth H 24 2nd Floor Window Glazing - Inconclusive Trace Ch 1 25 5th Floor Wall Plaster White Coat ND - - 1 26 4th Floor Wall Plaster White Coat ND - - 1 27 3 Floor Wall Plaster White Coat ND - - 1 28 2" Floor Wall Plaster White Coat ND - - 1 29 1St Floor Wall Plaster White Coat ND - - 1 30 1 Floor Wall Plaster White Coat ND - - 1 31 Basement Wall Plaster White Coat ND - - J 32 5th Floor Wall Plaster Brown Coat ND - - J 33 4th Floor Wall Plaster Brown Coat ND - - J 34 3 Floor Wall Plaster Brown Coat ND - - J 35 2" Floor Wall Plaster Brown Coat ND - - J 36 1 Floor Wall Plaster Brown Coat ND - - J 37 1 Floor Wall Plaster Brown Coat ND - - J 38 Basement Wall Plaster Brown Coat ND - - K 39 2" Floor Aircell Pipe Insulation 24% Ch - - K 40 Storefront Aircell Pipe Insulation NA/PS - - K 41 Basement Aircell Pipe Insulation NA/PS - - L 42 5th Floor Ceiling Plaster White Coat ND - - L 43 4th Floor Ceiling Plaster White Coat ND - - L 44 3 Floor Ceiling Plaster White Coat ND - - L 45 2" Floor Ceiling Plaster White Coat ND - - L 46 1 Floor Ceiling Plaster White Coat ND - - 47 j8t Floor Ceiling Plaster White Coat ND - - L L 48 Basement Ceiling Plaster White Coat ND - - M 49 5th Floor Ceiling Plaster Brown Coat ND - - M 50 4th Floor Ceiling Plaster Brown Coat ND - -

NYC-WTC 000135081

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000135081Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →