Environmental Site Characterization — Façade Report
Fiterman Hall —30 West Broadway, New York, NY
Airtek Project 05-0867 —January 10, 2006
TABLE I
SUMMARY OF BUILDING ENVELOPE INSPECTION RESULTS FOR ASBESTOS
F!TERMAN HALL 30 tNEST BROADWAY, NEW YORK. NY 10007
PROPOSED SUSPECT ACM THAT LAB APPROXIMATE
MAY BE AFFECTED RESULTS ACM QUANTITY N07ES18PECiFiC LOCATION
BWevr dram nwiatln of wwter NonACM --.~. Q BFI.- ...,Confirmed by Applied Technology
---. toner Services trio Ai 1988
Roof shingle of water tower Non ACM 0 SF Confirmed by Apped Technology
Services Inc Auc, 1996
Louvers of rooting tower Non ACM 0 SF Contamea by Applied Technology
— — Services tee Aug. 1996
Silicone caul 14on ACM C SF Confirmed by Applied Technology
Services Inc. Aug. 1996
Glazing Non ACM 0 SF Confirmed by Applied Technology
Services Inc. AtzO. 1996
Spandrez Hashing mastic ARCM 28.755 SF 1--15 Floor
Flashing mastic an beams AGM 25 SF Loading dock entrance
Slack cloth materials on ACM ,5 Leading dock entrance
Seems rontarrunated
Roof maleness Non ACM 0 SF Bevator mactune room root
Flashing Non AGM 0 SF Elevator machine zoom root
Copng caulk Non ACM 0 LF Elevator machine room toot
Cap flashing Non ACM C SF Elevator machine room tow
Screed Non ACM 0 SF Slevator machine room roof
Flashing Non ACM 0 SF Fan room rood
Roof materials Non ACM 0 SF Star roof
Flashing Non ACM 0 SF Stair roof
Top &SIde wmdowcauikr g ACM 1. LF . dab roof
Windowgleza+g Non ACM 0 IF Starr roof
Screed Non ACM 0 SF Steyr roof
Roof mails Non ACM 0 SF New elevamr mechanical room root
F+asnmq Non ACM 0 SF Newelevator mechan=s room rood
Coping alone caulk Non ACM 0 IF Newelevator mechanical room roof
Top & Side wrndowcautkerg ACM ! 2 IF Newelevator mechanical room roof
Screed Non ACM 0 SF Newelevator rnecharsrai room roof
matenals Non ACM 0 SF 15 Floor row
Flashing Non ACM OSF 15' Floor row
Ftastn9 Nom ACM 0 SF 14 Floor root
Roof membrane ACM 8980 SF 14 Floor roof
screed Non ACM 0 SF 14 Floor root
Root membrane under sawed Non ACM 0 SF 14 Floor root
Flashing Non ACM 0 SF 5 Floor ran
Root membrane Non A loot roof
Screed Non ACM asp 5 Flory rood
Brick wet mortar Non ACM 0 SF B 115 Floor
15
NYC-WTC 000096515
OCR can misread numbers and units. Confirm readings against the page image before using them.