Environmental Characterization Report
Fiterman Hall, 30 West Broadway, New York, NY
Airtek Project #05-0867 — January 10, 2006
APPROXItMA7
PROPOSED SUSPECT ACM THAT MAY LAB:
ANTI/ NOTEafSPECiFEC LOCATION
WORK BE AFFECTED RESULTS.
QUANTfTY
Acoustical ceiling We 4x2 and Non ACM 0 SF Confirmed by Applied Technology
2x2 Services Inc. Aug. 1996
Spray-on fireproofing Non ACM 0 SF Confirmed by Applied Technology
Services Inc. Au . 1898
Blue 12x12 VFT/mastic Non ACM 0 SF Confirmed by Applied Technology
Services Inc Au . 1998
Light grey 12"12 VFT/mastic Non ACM 0 SF Confirmed by Applied Technology
uce videe Inc. Aug. 1996
Tar materials on permeter ACM 28.755 SF t'-15 " Flaw
wall
Spandrel flashing mastic PACM 28,755 SF 1' -15 ' Floor
Paper maxis on perdm vas ACM 28.793 SF 2' -15 Floor
Fiber glass materials on ACM 28 793 SF 2" •15' ` Floor
perimeter walls Contaminated
Felt materials on perimeter ACM 1,962 SF 1' Floor
waits Contaminated
Flashing mastic on beams ACM 25 SF Loading dock entrance
Black cloth materials on ACM Loading dock entrance
25 SF
beams contaminated
Root materials Non ACM 0 SF Elevator machine room rod
Flashing Non ACM 0 SF Elevator machine room root
Coping caulk Non ACM 0 LF Elevator machine room root
Cap flashing Non ACM 0 SF Elevator machine room root
Screed Non ACM 0 SF Elevator machine room roof
Flashing Non ACM 0 SF Fan room roof
Roof materials Non ACM 0 SF Stair roof
Flashing Non ACM 0 SF Stair roof
Sloe window caulking ACM 8 LF Stair roof
Top window caulking ACM 4 LF Stair roof
Window glazing Non ACM 0 LF Stair roof
Screed Non ACM 0 SF Stair root
Root materials Non ACM 0 SF New elevator mechanical room root
Flashing Non ACM 0 SF New elevator mechanical room roof
Coping stone caulk Non ACM 0 LF New elevator mechanical room roof
Side window caulking ACM 8 LF New elevator mechanical room roof
Top window caulking ACM 4 LF New elevator mechanical room root
Steed Non ACM 0 SF New elevator mechanical room roof
Roof materials Non ACM 0 SF 15 ' Floor roof
Flashing Non ACM 0 SF 15" Floor roof
Flashing Non ACM 0 SF 14" Floor roof
Root membrane ACM 8.950 SF 14 Floor roof
Screed Non ACM 0 SF 14" Floor roof
Root membrane under screed Non ACM 0 SF 14" Floor roof
Flashing Non ACM 0 SF 5 Floor roof
Root membrane Non ACM 0 SF 5 Floor roof
Screed Non ACM 0 SF 5' ' Floor roof
Brick wall mortar Non ACM 0 SF 8" & IS' Floor