Preliminary environmental assessment report, 30 Warren Street, January 2006

Machine-extracted title · confidence 100%

Report cover for a preliminary environmental assessment regarding remediation at 30 Warren Street in January 2006.

NYC-WTC_000096567–000096622

Folder label: “201 WARREN STREET Block: 16 Lot: 220”

Page image
Scanned page image, NYC-WTC_000096594
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Characterization Report Fiterman Hall, 30 West Broadway, New York, NY Airtek Project #05-0867 — January 10, 2006

TABLE I SUMMARY OF INSPECTION RESULTS FOR ASBESTOS FITERMr`-? N '-IALL 30 to ST "lROA+DVVAY, NEW YORK, MY 10007

PROPOSED SUSPECT ACM THAT LAg APPROXIPBA WORK MAY ISE AFFECTED RESULTS TE ACM NOTESISPECIFIC LOCATION QUANTITY _ Elbow dram insulation of nester Non ACM 0 SF Confirmed by Applied Technology tower Serves Inc. Aug. 1996 Roof shingle of grater tower Non ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1596 Louvers of cooling tower Non ACM 0 S'r Confirmed by Applied Technology Services Inc Aug. 199$ Silicone caulk Non ACM 0 SF Confirmed by Applied Technology Services Inc Aug. 1998 Glazing Non ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1986 Gypsum walboard Non ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1998 Condenser gasket Non ACM 0 SF Confirmed by Applied Technology Servtces Inc Aug. 1996 Radiator backing Non ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1996 Hard vgll plaster Non ACM 0 SF Confirmed by Applied Technology Services Inc Aug. 1996 Fyrobar building block Non ACM 0 SF Confirmed bX Applied Technology Service€ lnc Aug. 1996 1 k patch on I-beam above Non ACM 0 SF Confirmed by Applied Technology warners a bathroom Services Inc- Aug1988 Cave moulding with glue Non .4CM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1996 Wall joint compound Not ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1996 Adhesive on dud-fiberglass Nan ACM 0 SF Confirmed by Applied Technology Services Inc Aug. 1996 Patch on duct insulators Non ACM 0 SF Confirmed by Applied Tecnnology Services Inc. Aug. 1996 Trowe®ed on cement on duct Non ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1998 MastictGlue paper Non ACM 0 SF Confirmed by Applied Technology Services Inc. Au . 1995 White speckled 9x8 VFT Non ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1.896 Grey speckled 9x9 VFT Non ACM 0 SF Confirmed by Applied Technology Services Inc Aug. 1996 Blue speckled 9x9 VFT Non ACM 0 c,F Confirmed by Applied Technology Services Ina Aug. 1996 Pipe wrapping in cage Non ACM 0 SF Confirmed by Applied Technology Services Inc. Aug. 1986 Mudded joist fitting elbow lion ACM 0 SF Confirmed by Applied Technology a Services Inc. Aug 1996 White 12x12 VFTlmasarc Non ACM 0 SF Confirmed by Applied Technology Services Inc Aug. 1996 Beige 12-12 vFllmastic Non ACM 0 SF Confirmed by Applied Technology Services Inc Au . 1596

NYC-WTC 000096594

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000096594Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →