NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 52/BINDER - PHASE 1 DECONTAMINATION PLAN
Document / 34 pages

Final Asbestos Report, 21-23 Thames Street, May 2005

Machine-extracted title · confidence 100%

Final asbestos report conducted by Airtek Environmental Corp for the Greenwich Street Project LLC in May 2005.

NYC-WTC_000127695–000127728

Folder label: “BINDER - PHASE 1 DECONTAMINATION PLAN

Page image
Scanned page image, NYC-WTC_000127703
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Homogeneous Sample Area ___________ M # Location _______ ___________ 53 1 Floor ____________________O Material Ceiling Plaster Brown Coat PLM Results ND PLM-NOB - TEM-NOB - M 54 1 Floor Ceiling Plaster Brown Coat ND - - M 55 Basement Ceiling Plaster Brown Coat ND - - N 56 Basement Aircell Pipe Insulation 27% Ch - - N 57 Basement Aircell Pipe Insulation NA/PS - - N 58 Basement Aircell Pipe Insulation NA/PS - - O 59 1 Floor Rubber Tile Mastic - Inconclusive ND O 60 1 Floor Rubber Tile Mastic - Inconclusive ND O 61 1 Floor Rubber Tile Mastic - Inconclusive ND P 62 5 Floor Sheetrock ND - - P 63 3 Floor Sheetrock ND - - P 64 1 Floor Sheetrock ND - - Q 65 5 Floor Joint Compound ND - - Q 66 3 Floor Joint Compound ND - - Q 67 1 Floor Joint Compound ND - - Cementitious Duct ND - - R 68 1 Floor insulation Cementitious Duct R 69 1 Floor ND - - insulation 1" t Floor Cementitious Duct ND - - R 70 insulation White Block Pipe 16% Amo - - S 71 1'd Floor Insulation 4% Ch White Block Pipe S 72 1 Floor NA/PS - - Insulation White Block Pipe S 73 1s` Floor NA/PS - - Insulation T 74 1 Floor Tile Grout ND - - T 75 1 Floor Tile Grout ND - - T 76 1 Floor Tile Grout ND - -

NYC-WTC 000127703

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000127703Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →