NYC-WTC_000086768
Calibration data table for GC/MS analysis of WTC samples conducted on October 2, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Document containing tabular laboratory data including pH and count metrics for environmental sample analysis in November 2001.
NYC-WTC_000069154–000069181Folder label: “GCMS Scan X 10/19/01 An 11/8/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report Data File : C:\HPCHEM\1\DATA\NOV0801\LBA.D Vial: 8 Acq On : 8 Nov 2001 9:26 pm Operator: 209 GALOS Sample : 10/19 lab blk Inst : GC/MS 209 Mise : Multiplr: 1.00 MS Integration Params: LSCINT.P
Quant Method : C:\HPCHEM\1\METHODS\NP103001.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 12 Pentadecane, 8-hexyl- Concentration Rank 6 R.T. EstConc Area Relative to ISTD R.T, 34.56 4.90 ug/1 2065290 Chrysene-dl2 33.07 Hit# of 5
p Tentative ID MW MolForm CAS# 1 Pentadecane, 8-hexyl- 296 C21H44 013475-75-7 2 Tridecane, 7-hexyl- 268 C19H40 007225-66-3 3 Eicosane, 10-methyl- 296 C21H44 054833-23-7 93 4 Heneicosane 296 C21H44 000629-94-7 91 Abundance Scan 3215 (34.556 min): LBA.D (-) m/z 57
85 slw! 4
TTfe-> 40 J ttYI 60 197 225 yTTTTp-TTTyTTT-rpTmyrTTTpT^ 253 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 295 323 351 380 I'''' I'''' I 34.20 34.40 34.60 34.80 m/z 71.10 72.06% Abundance #42199: Pentadecane, 8-hexyl- 413 71 / 5000 I ' ' ’ ' I 34.20 34.40 34.60 34.80
196 m/z 43.05 68.84% I1 I ,1 127 I , 266 296___________ r ‘' 'I"' ‘ I " " I I'''' I'''' I'''' I'' " I' ’'' I ‘‘ I'''' I Tife-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 Abundance #37464: Tridecane, 7-hexyl- 57 / V.................. 34.20 34.40 34.60 34.80 5000 85 54.04% 182
I Il 240 268 I II 11j 1 ill I n 11J11 ' I ’ ” ' p ' •«I • " • I' ’ • ri iTi I I" "I ""I Ti/z-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 Abundance #42197: Eicosane, 10-methyl- 5|7 34.20 34.40 34.60 34.80 m/z 41.05 24.19% 5000 85
I 1 154
■nfe-> JULU t 268 296 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 I " “ I'''' I 34.20 34.40 34.60 34.80
LBA.D NP103001.M Mon Nov 19 14:43:44 2001 Page 12
NYC-WTC_000069171
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000086768
Calibration data table for GC/MS analysis of WTC samples conducted on October 2, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088700
Instrument calibration report for GC/MS Method NP091101 used for TCLP analysis, generated on October 16, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000089278
GC/MS calibration table listing compounds like 1,4-Dichlorobenzene-d4 and Naphthalene-d8 from October 2001.
1 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088184
Instrument output displaying chromatographic peaks and integration parameters for a laboratory blank analyzed on October 12, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086624
Calibration data table for GC/MS analysis of polycyclic aromatic hydrocarbons dated October 2001.
1 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086788
Calibration data table for GC/MS analysis of WTC samples conducted on October 2, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087132
Calibration data table for GC/MS analysis using the TCLP method, generated on October 3, 2001, listing standard compounds and response factors.
1 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087980
Laboratory data sheet listing extraction dates and calibration results for deuterated standards.
1 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087496
Calibration table and chromatographic data for the TCLP method using GC/MS instrument 209, dated October 3, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086981
Calibration data table for TCLP analysis including retention times and response factors for various compounds.
1 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000030685
Header page for a gas chromatography-mass spectrometry scan file related to environmental testing at the World Trade Center site.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000089030
GC/MS analysis report with TCLP calibration table data from October 16, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000086768
Calibration data table for GC/MS analysis of WTC samples conducted on October 2, 2001.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088774
Laboratory report documenting GC/MS analysis of sample AD23498 conducted on October 19, 2001.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087773
Laboratory report documenting GC/MS analysis of sample AD22979 conducted on October 10, 2001, identifying unknown compounds.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088263
Laboratory report documenting GC/MS analysis of sample AD23322 conducted on October 15, 2001.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088115
Laboratory report documenting GC/MS analysis of sample AD23262 conducted on October 12, 2001.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000087202
Laboratory report documenting GC/MS analysis of sample AD22580 conducted on October 11, 2001, identifying unknown compounds.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000069150
Record of a GCMS scan conducted at the World Trade Center site in mid-November 2001.
Filed in the same folder
NYC-WTC_000069151
Fragmented laboratory data record from a GCMS scan performed in November 2001 regarding environmental samples.
Filed in the same folder
NYC-WTC_000069182
Gas chromatography/mass spectrometry analysis of sample AD24980 conducted November 19, 2001, identifying other unknown compounds.
Filed in the same folder
NYC-WTC_000069193
Laboratory report documenting GCMS analysis of sample AD24981 conducted on November 19, 2001, identifying unknown compounds.
Filed in the same folder
NYC-WTC_000069204
Laboratory report documenting GCMS analysis of sample AD25037 conducted on November 19, 2001, identifying unknown compounds.
Filed in the same folder