NYC-WTC_000011080
Calibration table listing retention times and concentrations for TCLP method analysis in March 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Gas chromatography-mass spectrometry analysis of sample AE01156 conducted March 29, 2002, showing surrogate standard 2,4-DDD recovery.
NYC-WTC_000059687–000059692Folder label: “GCMS X 3/13/02 A 3/27/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\1\DATA\MAR21O2\REFA1.D Vial: 17 Acq On : 22 Mar 2002 3:04 am Operator: Sample : gc/ms scan 3/13 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: Mar 25 8:51 2002 Quant Results File: GCMS0308.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0308.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Fri Mar 08 08:54:27 2002 Response via : Initial Calibration DataAcq Meth : GCMS0308
Compound R.T. Qlon Response Cone Unit Qvalue
30)■N-Nitrosodiphenylamine 23.24 168 138873 9.16 ug/1 # 80 31) 4-Bromophenyl-phenylether 24.31 248 97920 10.99 ug/1 93 32) Hexachlorobenzene 24.75 284 115833 11.20 ug/1 # 89 3 3) Phenanthrene 25.73 178 536900 11.08 ug/1 99 34) Anthracene 25.85 178 501054 10.43 ug/1 99 35) Di-n-butylphthalate 27.63 149 690764 11.33 ug/1 99 36) Fluoranthene 29.35 202 542332 10.67 ug/1 95 39) Pyrene 30.02 202 561243 13.62 ug/1 # 91 40) Butylbenzylphthalate 32.15 149 251510 11.84 ug/1 97 41) Benzo(a)anthracene 33.67 228 369171 10.77 ug/1 99 42) Bis (2-ethylhexyl) phthalate' 33.93 149 333414 11.62 ug/1 95 43) Chrysene 33.80 228 390911 11.63 ug/1 98 45) Di-n-Octylphthalate 35.68 149 398311 10.39 ug/1 # 97 46) Benzo(b)fluoranthene 36.78 252 310764 11.70 ug/1 98 47) Benzo (]<) fluoranthene 36.84 252 334880 12.93 ug/1 98 48) Benzo(a)pyrene 37.77 252 219098 9.05 ug/1 # 96 49) Indeno(1,2,3-cd)pyrene 42.11 276 234318 8.02 ug/1 95 50) Dibenz(a,h)anthracene 42.19 278 200509 8.86 ug/1 98 51) Benzo (g, h, D perylene 43.35 276 206983 8.68 ug/1 96
(#) .= qualifier out of range (m) = manual integration REFAl.D GCMS0308.M Mon Mar 25 09:00:48 2002 Page 2
NYC-WTC_000059688
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000011080
Calibration table listing retention times and concentrations for TCLP method analysis in March 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011132
Laboratory report showing GC/MS calibration data and surrogate recovery for sample AE03078 on March 22, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011189
Laboratory report showing GC/MS calibration data and surrogate recovery for sample AE03182 on March 22, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011121
Laboratory report showing GC/MS calibration data and surrogate recovery for sample AE03077 on March 22, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011200
Laboratory report showing GC/MS calibration data and surrogate recovery for sample AE03183 on March 22, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009667
Calibration table page listing internal standards and response factors for GCMS analysis.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011174
Laboratory report showing GC/MS calibration data and surrogate recovery for sample AE03181 on March 22, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000038116
Calibration data table for GC/MS analysis of TCLP samples listing retention times and response values for deuterated standards.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023017
Laboratory report detailing gas chromatography mass spectrometry analysis of sample AE09570 conducted on May 14, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000010394
Laboratory report showing GC/MS calibration data for polycyclic aromatic hydrocarbons on February 27, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000011162
Laboratory report showing GC/MS calibration data and surrogate recovery for sample AE03180 on March 22, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052575
Instrument data file from February 2002 listing retention times and concentrations for polycyclic aromatic hydrocarbon surrogates.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000059660
Administrative record from the Department of Environmental Protection regarding World Trade Center activities in March 2002.
Filed in the same folder
NYC-WTC_000059661
Technical record detailing laboratory method parameters including drip rates, solvent lots, and extraction type logs.
Filed in the same folder
NYC-WTC_000059666
Laboratory report detailing GCMS analysis of environmental sample AE01156 conducted on March 25, 2002.
Filed in the same folder
NYC-WTC_000059670
Laboratory report showing GCMS blank analysis results for sample AE01156 conducted on March 25, 2002, with compound detection limits.
Filed in the same folder
NYC-WTC_000059679
Reference data report listing component names and response values for calibration verification conducted on March 25, 2002.
Filed in the same folder