NYC-WTC_000039303
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
NYC-WTC_000039312–000039314Folder label: “GCMS X 3/18/02 A 4/8/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
a Quantitation Report (QT Reviewed)
Data File C:\MSDCHEM\1\DATA\020408\0408C5.D Vial: 6 Acq On 8 Apr 2002 3:33 pm Operator: McLean Sample Inst : Instrumen Mise Multiplr: 1.00 MS Integration Params: EVENTS.E Quant Time: Apr 09 15:11:38 2002 Quant Results File: SCANAPR0902 .R
Quant Method : C:\MSDCHEM\1...\SCANAPR0902. M (Chemstation Integrator) Title : Method 508 GC/MS Scan Last Update : Tue Apr 09 15:05:54 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN1
Compound R.T. Qlon Response Cone Unit Qvalue
34) Phenanthrene 31.06 178 40010875 79.12 ug/1 99 35) Anthracene 31.30 178 39793218 81.12 ug/1 100 36) Di-n-butylphthalate 34.02 149 42560057 83.57 ug/1 100 37) Fluoranthene 35.28 202 43189958 83.21 ug/1 98 40) Pyrene 35.89 202 44307873 - 77.70 ug/1 98 41) Buthylbenzylphthalate 38.12 149 18062678 85.05 ug/1 95 42) Benz(a)anthracene 39.12 228 37134353 83.86 ug/1 100 43) Chrysene 39.21 228 34840703 80.24 ug/1 98 44) Bis(2-ethylhexyl)phthalate 39.70 149 21150686 87.53 ug/1 97 46) Di-n-Octyl phthalate 41.21 149 30401014 81.54 ug/1 97 47) Benzo(b)fluoranthene 41.57 252 28859538 93.35 ug/1 99 48) Benzo(k)fluoranthene 41.65 252 29832975 83.99 ug/1 98 49) Benzo(a)pyrene 42.22 252 24560545 94.22 ug/1 96 50) Indeno(1,2,3-cd)pyrene 44.39 276 13765569 77.23 ug/1 98 51) Dibenz(a,h)anthracene 44.48 278 12912229 86.63 ug/1 98 52) Benzo(ghi)perylene 44.95 276 13086790 84.72 ug/1 98
(#) = qualifier out of range (m) = manual integration (+) = signals summed 0408C5.D SCANAPR0902 . M Tue Apr 09 15:12:01 2002 Page 2
NYC-WTC_000039313
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000039303
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039306
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039300
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039320
Laboratory report documenting GCMS reference analysis of sample AE06303 conducted on April 9, 2002.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039296
Calibration report for Method 508 GC/MS analysis performed on April 9, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044458
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044467
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044455
Calibration data for GCMS analysis of volatile organic compounds with response factors recorded on May 2 2002.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044464
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000015771
Quantitative report for a gas chromatography-mass spectrometry calibration standard verifying internal standard responses.
1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044461
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000048620
Gas chromatography-mass spectrometry results for sample AE08482 including surrogate recovery data.
1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000039296
Calibration report for Method 508 GC/MS analysis performed on April 9, 2002, listing internal standards.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039306
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039300
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039306
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039303
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039320
Laboratory report documenting GCMS reference analysis of sample AE06303 conducted on April 9, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000039286
Department of Environmental Protection site log sheet for the World Trade Center area covering March and April 2002.
Filed in the same folder
NYC-WTC_000039287
Fragmented document header from the Department of Environmental Protection archive covering March to April 2002.
Filed in the same folder
NYC-WTC_000039288
Laboratory report detailing GCMS analysis of sample AE06303 conducted on April 10, 2002.
Filed in the same folder
NYC-WTC_000039296
Calibration report for Method 508 GC/MS analysis performed on April 9, 2002, listing internal standards.
Filed in the same folder
NYC-WTC_000039300
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
Filed in the same folder