NYC-WTC_000039306
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
NYC-WTC_000039300–000039302Folder label: “GCMS X 3/18/02 A 4/8/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C: \MSDCHEM\1\DATA\020408\0408C1.D Vial: 2 Acq On 8 Apr 2002 11:49 am Operator: McLean Sample Inst : Instrumen Mise Multiplr: 1.00 MS Integration Params: EVENTS.E Quant Time: Apr 10 14:24:16 2002 Quant Results File: SCANAPR0902.R
Quant Method : C:\MSDCHEM\1...\SCANAPR0902.M (Chemstation Integrator) Title : Method 508 GC/MS Scan Last Update : Tue Apr 09 14:51:40 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN1
Compound R.T. Qlon Response Cone Unit Qvalue
34) Phenanthrene 30.99 178 2227868 4.89 ug/1 100 35) Anthracene 31.21 178 2035215 4.60 ug/1 98 36) Di-n-butylphthalate 33.98 149 1833706 4.00 ug/1 100 37) Fluoranthene 35.22 202 2051125 4.39 ug/1 95 40) Pyrene 35.83 202 2169872 4.83 ug/1 95 41) Buthylbenzylphthalate 38.09 149 369485 (2.21 ug/1 87 42) Benz(a)anthracene 39.08 228 1490776 4.27 ug/1 99 43) Chrysene 39.15 228 1625065 4.75 ug/1 100 44) 46) 47) Bis(2-ethylhexyl)phthalate Di-n-Octyl phthalate Benzo(b)fluoranthene 39.68 41.18 41.52 149 149 252 343220 334090 858426 9:80-ug/1 (3.43-ug/1 90 86 95 48) Benzo(k)fluoranthene 41.58 252 1363514 4.74 ug/1 95 49) Benzo(a)pyrene 42.17 252 633453 /3.00 ug/1 94 50) Indeno(1,2,3-cd)pyrene 44.35 276 197362 ug/1 89 51) Dibenz(a,h)anthracene 44.45 278 264593 / 2.19ug/l 92 52) Benzo(ghi)perylene 44.89 276 444096 l 3.55 ug/1 95
(#) = qualifier out of range (m) = manual integration (+) = signals summed 0408C1.D SCANAPR0902.M Wed Apr 10 14:25:19 2002 Page 2
NYC-WTC_000039301
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000039306
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039320
Laboratory report documenting GCMS reference analysis of sample AE06303 conducted on April 9, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039312
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039303
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039296
Calibration report for Method 508 GC/MS analysis performed on April 9, 2002, listing internal standards.
1 shared topics · Same agency, volume and box · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044458
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044455
Calibration data for GCMS analysis of volatile organic compounds with response factors recorded on May 2 2002.
1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044467
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044464
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000015771
Quantitative report for a gas chromatography-mass spectrometry calibration standard verifying internal standard responses.
1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044461
Calibration scan report for EPA Method 508 showing retention times and deviations for deuterated standards on May 2 2002.
1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000048620
Gas chromatography-mass spectrometry results for sample AE08482 including surrogate recovery data.
1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000039286
Department of Environmental Protection site log sheet for the World Trade Center area covering March and April 2002.
Filed in the same folder
NYC-WTC_000039287
Fragmented document header from the Department of Environmental Protection archive covering March to April 2002.
Filed in the same folder
NYC-WTC_000039288
Laboratory report detailing GCMS analysis of sample AE06303 conducted on April 10, 2002.
Filed in the same folder
NYC-WTC_000039296
Calibration report for Method 508 GC/MS analysis performed on April 9, 2002, listing internal standards.
Filed in the same folder
NYC-WTC_000039303
Calibration report for Method 508 GC/MS analysis performed on April 10, 2002, listing internal standards.
Filed in the same folder