Asbestos Abatement
2. For PCM analysis, the clearance air monitoring shall be considered
satisfactory when each of the 5 inside/5outside samples for Large Projects
and/or 3 inside/3outside samples for Small Projects is less than or equal to
0.01 f/cc or the background concentrations, whichever is greater.
3. For TEM analysis, the clearance air monitoring shall be considered
satisfactory when the requirements stated in 40 CFR Part 763, Subpart E,
Appendix A, Section IV are met.
4. As soon as the air monitoring tests are completed, the Testing Laboratory
will send the results of such tests to the City and notify the Contractor.
The Contractor shall cooperate fully with all aspects of air monitoring operations.
1.19 TAMPERING WITH TEST EQUIPMENT
A. All parties to this Contract are hereby notified that any tampering with testing
equipment will be considered an attempt at falsifying reports and records to
federal and state agencies and each offense will be prosecuted under applicable
state and federal criminal codes to the fullest extent possible.
1.20 GUARANTEE
A. Work performed in compliance with this Contract shall be guaranteed for a period
of one year from the date the completed work is accepted by the City.
B. The Contractor shall not be held liable for the guarantee where the repair required
under the guarantee is a result of obvious abuse or vandalism, as determined by
the Commissioner.
C. The City will notify the Contractor in writing regarding defects in work under the
guarantee.
Part 2 - PRODUCTS
2J MATERIAL HANDLING
A. Deliver all materials to the job site in their manufacturer's original container, with
the manufacturer's label intact and legible.
1. Maintain packaged materials with seals unbroken and labels intact until
time of use.
2. Store all materials on pallets, away from any damp and/or wet surface.
Cover materials in order to prevent damage and/or contamination.
CAPITAL PROJECT NUMBER PO79201K 02081-46
100: CONTRACT DOCUMENTS REV. May 3,2000