NYC 9/11 Public Portal Document
Asbestos Abatement
(3) Submit all changes in schedule or staffing to the Resident
Engineer prior to implementation.
(4) A schedule of equipment to be used including numbers and
types of all major equipment such as HEPA Air Eiltration
Units, HEPA-vacuums, airless sprayers. Water Atomizing
Devices and Type "C" compressors.
e. A written plan and shop drawings for preparation of work site and
decontamination chamber.
f. Description of protective clothing and approved respirator to be
used, make, model, NIOSH approval numbers.
g. Delineation of responsibility of work site supervision, including
competent person, with names, resumes, and home telephone
numbers.
h. Explanation of decontamination sequence and isolation techniques.
1. Description of specific equipment to be utilized, including make
and model number of air filtration devices, vacuums, sprayers, etc.
j- Description of any prepared methods, procedures, techniques, or
equipment other than those specified in the Contract Documents.
k. Explanation of the handling of contaminated wastes including EPA
and NYCDEP identification numbers of Waste Hauler.
1. Description of the final clean-up procedures to be used.
m. Name and qualifications of Contractor's testing laboratory
including AIHA accreditation, and proof of NIOSH PAT and
NTST/NVLAP Bulk Quality Assurance Proficiency of OSHA
samples for approval by the City of New York Department of
Design and Construction.
n. Written description of emergency procedures to be followed in
case of injury or fire. This section must include evacuation
procedures, source of medical assistance (name and telephone
number) and procedures to be used for access by medical
personnel (examples: first aid squad and physician). NOTE:
Necessary Emergency Procedures Shall Take Priority Over All
Other Requirements of These Specifications.
o. Material Safety Data Sheets (MSDS) for encapsulants, sealants,
CAPITAL PROJECT NUMBER PO79201K 02081-24
100: CONTRACT DOCUMENTS REV. May 3,2000
- 24 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631273
NYC-WTC_000416785
OCR can misread numbers and units. Confirm readings against the page image before using them.