NYC 9/11 Public Portal Document
Asbestos Abatement Technical Specifications
For 130 Cedar Street, New York, NY
information to the examining physician regarding unusual conditions in the
• work place environment (e.g., high terr~peratures, humidity and chemical
contaminants) that may impact on the employees' ability to perform work
activities.
1.7 A copy of the Contractor's and all Sub-Contractors' insurance certificates.
1.8 Manufacturer's certification that HEPA vacuums, required HEPA equipped
ventilation units and other local exhaust ventilation equipment conform to
ANSI Z9.2-79.
1.9 When rental equipment is to be used in abatement area or to transport
asbestos contaminated waste, a written notification concerning intended use
of the rental equipment must be provided to the rental agency with a copy
submitted to the Owner(s)
1.10 MSI-IA/NIOSH approval documents for Iall respiratory protective devices
utilized on site, including manufacturer certification of HEPA filtration
capabilities for all cartridges and filters
1.11 Respiratory system information, including manufacturer's literature
describing the air supply system and illustrating that it meets the
specifications on supplying Grade "D" breathing air.
1.12 Copies of the Contractor's training program, safety manuals and policies,
and his written respiratory protection program.
1.13 Standard operating procedure showing how workmen, visitors and Owner's
employees will be protected from exposure, how space outside the work
areas will be protected from contamination through completion of work, work
procedures utilized during the project and final clean-up/decontamination
procedures to be implemented.
1.14 The system, warning signs and labels for bags and drums.
1.15 Fire and emergency evacuation plan.
1.16 Plan for communication system between work area and outside (if
necessary).
1.17 . Engineering systems for exposure control showing the number, location and
capacity of air supply and exhaust systei`ns, the expected direction of flow
and the maximum and minimum negative pressure allowed for each work
area.
1.18 A list of equipment planned for use during this project, including
manufacturer's literature and certifications if appropriate.
1.19 The Identification of encapsulant and material safety data sheets (MSDS).
is 1.20 The telephone location with ready access.
Prepared by JLC Environmental Consultants, Inc. Project No. 04-3271 Page 24
NYC-WTC 000125602
OCR can misread numbers and units. Confirm readings against the page image before using them.