2. Air monitoring technicians must be • .-site during clean-up activities to collect final clearance samples. 3. The Project Monitor shall ensure that the clean up activities comply with the NYCDEP Scope of Work.
Post Clean-up Air Sampling Procedure must be as followed:
a) Sampling shall not begin until a visual inspection confirms the absence of visible debris.
b) All surfaces must be completely dry prior to the start of sampling.
c) Sampling equipment shall be placed at representative locations within the work area and away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces.
d) Air conditioning units where applicable shall be run/operated at least I j minutes prior to the start of sampling. The air conditioning units shall ope- ate continuously throughout the sampling. HVAC systems shall be in operation during sampling.
e) Forced air equipment (e.g. leaf blowers) may be used only after written authorization by the occupant or his/her authorized representative. The project manager shall advise the occupant or his/her authorized representative on the advantages and disadvantages regarding the use of the equipment and obtain the individual’s signature authorizing use. Before the start of sampling, forced air equipment (such as a 1 horsepower leaf blower) may be used to direct exhaust air against walls, ceilings, floor, ledges and other surfaces. When directing the exhaust, caution shall be taken to minimize disturbance and potential damage to furnishings and personal belongings.
f) One 20-inch fan shall be installed per 10,000 cubic feet of room space and run at low speed. The fan shall operate continuously throughout sampling and shall not be turned off until sampling is completed.
g) For studio apartments 3 samples shall be collected. For 1-bedroom apartments and above 5 samples shall be collected. Technicians shall collect a volume of 3000 liters per sample using a flow rate of 10 liters per minute.
h) Samples must be labeled and accompanied with completed chain of custody forms before shipping to the designated laboratory.
i) Project Monitor shall perform all final visual inspections.
j) All information must be maintained on a data based software program that is acceptable to the USEPA.
4. Project reports, including a project completion sign-off signed by the project monitor and the occupant or his/her authorized representative, must be typed and forwarded to USEPA with a copy to NYCDEP.
CITY_21MC100_011961546
NYC-WTC_000408465
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000362919
Qualifications and monitoring requirements for asbestos air sampling.
6 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408623
Contract monitor requirements and qualifications for asbestos projects.
6 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000233762
Contract outlining requirements for asbestos project monitoring and air sampling at the World Trade Center site.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455863
Contract requirements and qualifications for asbestos monitoring and air sampling personnel.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234300
Contract document outlining requirements for project monitors and air sampling technicians for the WTC debris cleanup and air monitoring.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234543
Contract document establishing compliance requirements and qualifications for monitors conducting debris cleanup and air sampling near the World Trade Center site.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234342
Contract excerpt outlining compliance requirements and qualifications for monitors and technicians involved in WTC debris cleanup.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434333
Contract document establishing compliance requirements and qualifications for monitors conducting debris cleanup and air sampling near the World Trade Center site.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362539
Scope of work for asbestos abatement monitoring and sampling at 114 Liberty Street, Manhattan.
4 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330742
Monitoring contractor requirements for on-site asbestos air sampling and clearance measurements.
5 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151286
Contract outline defining compliance requirements and personnel qualifications for monitoring debris cleanup and air sampling near the World Trade Center.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140337
Details project scope for scheduling, coordinating, and monitoring dust and debris cleanup with air sampling from apartments affected by World Trade Center collapse.
7 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000362919
Qualifications and monitoring requirements for asbestos air sampling.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140603
Contract establishing requirements for third-party asbestos monitoring and air sampling in residential buildings.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000147982
A project proposal outlining the timeline, methods, and justification for cleaning HVAC systems in residential units affected by World Trade Center dust.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151286
Contract outline defining compliance requirements and personnel qualifications for monitoring debris cleanup and air sampling near the World Trade Center.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408623
Contract monitor requirements and qualifications for asbestos projects.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151295
Contract document dated June 11, 2002, outlining scope of work for debris cleanup monitoring and air sampling at the World Trade Center site.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000362919
Qualifications and monitoring requirements for asbestos air sampling.
Similar indexed content
NYC-WTC_000151286
Contract outline defining compliance requirements and personnel qualifications for monitoring debris cleanup and air sampling near the World Trade Center.
Similar indexed content
NYC-WTC_000408623
Contract monitor requirements and qualifications for asbestos projects.
Similar indexed content
NYC-WTC_000233762
Contract outlining requirements for asbestos project monitoring and air sampling at the World Trade Center site.
Similar indexed content
NYC-WTC_000455863
Contract requirements and qualifications for asbestos monitoring and air sampling personnel.
Similar indexed content