ASBESTOS PROJECT MONITOR AND AIR SAMPLING CONTRACT
A. Introduction
All work performed under this contract must be in compliance with all applicable, relevant, and
appropriate regulations and Scope of Work, including but not limited to those of the United States
Environmental Protection Agency (USEPA), the United States Department of Labor, Occupational Safety
and Health Administration (USOSHA), the New York State Department of Labor (NYSDOL), the New
York State Department of Health Environmental Laboratory Approval Program (ELAP) and the New
York City Department of Environmental Protection (NYCDEP). This project shall involve coordinating
and monitoring the clean up of debris and air sampling from building apartments in the vicinity of the
World Trade Center explosion site.
C. B. Qualifications
Project Monitors
The Project Monitors must possess valid NYS Asbestos Project Monitor certificates. Monitors must have
served a third party project monitor on at least 20 asbestos abatement projects. Project Monitor must have
performed final clearance inspections on at least 50 asbestos abatement projects.
Technicians
Air monitoring technicians must possess valid NYS Asbestos Project Sampling Technician (APST)
certificates. Technicians must have performed air sampling for at least 2 years.
Proof of qualifications must be presented upon request.
Equipment
Sampling equipment must be in sufficient quantity to provide the amount and type of samples required for
this project. At a minimum the following equipment are required: air-sampling pumps with flow rate
capacities of 2 to 10 liters per minute, tripods, rotometers, sample cassettes with mixed cellulose ester
filters having pore size of 0.45um(TEM).
C. Specifications
The Project Monitor shall direct and coordinate all services and report all findings to USEPA. The scope
of this project will be as followed:
1. The Project Monitors shall be responsible for receiving complaints from the EPA Hotline, scheduling
cleaning-up activities and air sampling with the tenants/owners, asbestos abatement contractors
and air monitoring technicians to the various apartments.
2. Air monitoring technicians must be on-site during clean-up activities to collect final clearance
samples.
CITY_21MC100_008756207
NYC-WTC_000455863
OCR can misread numbers and units. Confirm readings against the page image before using them.