NYC-WTC_000138626
Distribution of revised scopes of work documents for WTC indoor cleaning and monitoring contracts.
10 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗Contract document dated June 11, 2002, outlining scope of work for debris cleanup monitoring and air sampling at the World Trade Center site.
NYC-WTC_000151295–000151300Folder label: “CONTRACTS CONTRACTORS - See: $ matrics etc file”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
JUN-11-2002 14:30 U.S. EPA REGION 2 REPP 906 906 6182 P.03/07 ,*
2. Air monitoring technicians must be on-site during clean-up activities to collect final clearance •samples. 3. The Project Monitor shall ensure that the clean up activities comply with the NYCDEP Scope of Work.
Post Clean-up Air Sampling Procedure must be as followed:
a) Sampling shall not begin until a visual inspection confirms the absence of visible debris.
b) All surfaces must be completely dry prior to the start of sampling.
c) Sampling equipment shall be placed at representative locations within the work area and away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces.
d) Air conditioning units where applicable shall be run/operated at least 15 minutes prior to the start of sampling. The air conditioning units shall operate continuously .throughout the sampling. HVAC systems shall be in operation during sampling.
e) Forced air equipment (e.g, leaf blowers) may be used only after wriiien authorization by the occupant or his/her authorized representative. The project manager shall advise the occupant or his/her authorized representative on the advantages and disadvantages regarding the use of the equipment and obtain the individual's signature authorizing use. Before the start of sampling, forced air equipment (such as a 1 horsepower leaf blower) may be used to direct exhaust air against walls, ceilings, floor, ledges and other surfaces. When directing the exhaust, caution shall be taken to minimize disturbance and potential damage to furnishings and personal belongings.
f) One 20-inch fan shall be installed per 10,000 cubic feet of room space and run at low speed. The fan shall operate continuously throughout sampling and shall not be turned off until sampling is completed.
g) For studio apartments 3 s^ples shall be collected. For 1-bedroom apartments and above 5 samples shall be collected. Technicians shall collect a volume of 3000 liters per sample using a flow rate of 10 liters per minute.
h) Samples must be labeled and accompanied with completed chain of custody forms before shipping to the designated laboratory.
i) Project Monitor shall perform all final visual inspections.
j) All information must be maintained on a data based software program that is acceptable to the USEPA.
1. Project reports, including a project completion sign-off signed by the project monitor and the occupant or his/her authorized representative, must be typed and forwarded to USEPA with a copy to NYCDEP.
NYC-WTC_000151296
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000138626
Distribution of revised scopes of work documents for WTC indoor cleaning and monitoring contracts.
10 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161167
Forwarded draft Statements of Work for cleaning and monitoring activities requiring review by noon.
10 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138725
EPA transmits revised scopes of work for WTC indoor cleaning and monitoring contracts to DEP.
10 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162352
EPA request for review and feedback on draft scope of work documents for WTC cleaning and air monitoring contractors.
10 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138918
Internal DEP correspondence discussing EPA draft scope of work for WTC program and clarifying agency roles and responsibilities.
7 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139101
EPA transmits revised scopes of work documents for the indoor dust cleaning and monitoring program, including cleaning SOW #7 and monitoring SOW #7.
9 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139209
Administrative notice instructs staff to preserve original World Trade Center documents for potential litigation.
7 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139232
DEP requests review of attached Scope of Work documents for mold remediation and air monitoring contracts.
7 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138743
EPA circulates latest draft scopes of work for WTC indoor dust cleaning program requesting comments.
10 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
A notice instructing that original World Trade Center documents must be preserved as evidence and not disposed of due to potential legal actions.
Filed in the same folder
Report establishing health-based screening levels for the indoor environment with cross-agency representation.
Filed in the same folder
Letter confirming contractor responsibility for cleaning residences and HVAC systems in accordance with project scope.
Filed in the same folder
Confidential cover sheet from the U.S. Environmental Protection Agency regarding a specific confirmation item.
Filed in the same folder
NYC-WTC_000151148
EPA coordination memo regarding identification and contact of eligible apartment requests for WTC testing and cleaning.
Filed in the same folder