NYC 9/1J^u bl IC Portal Document JUN-11-2002 14:31 U.S. EPA REGION 2 REPP 908 90S 6182 P.04Z07

Indoor Clean-up Activities

Scope of Work A

Application: These procedures apply to the clean-up of minimal dust accumulations (light coating). Cleaning shall include HEPA- vacuuming and wet-wiping. If a visual inspection indicates the presence of large debris accumulations from the collapse of the WTC, then these procedures shall not be applicable (refer to Scope of Work B). The USEPA coordinator must be contacted immediately with information regarding the presence of debris. The contractor shall not proceed with work until the USEPA coordinator provides a determination regarding appropriate procedures.

1. All work shall be performed by a NYS DOL licensed contractor with NYS DOL- and NYC DEP- certified workers. The clean-up activities must be performed in the presence of an authorized individual/occupant who shall be responsible for personal belongings.

2. A third party air monitoring firm shall perform air sampling after the clean up activities. The person who conducts sampling shall possess a valid NYS DOL certificate.

3. Individuals performing clean up activities are not required to wear personal protective equipment or respirators.

4. All surfaces shall be wet wiped/HEPA vacuumed. An encapsulating agent shall not be applied. Surfaces include but are not limited to walls, floors, ceilings, ledges, trims, furnishings, appliances, equipment, etc.

Carpets, curtains, upholstery, and other materials that cannot be cleaned by wet wiping shall be HEPA vacuum^ two times. Dry sweeping is prohibited. Plants shall be cleaned by rinsing leaves with water. Paperwork and books shall be HEPA vacuumed. Clothing and accessories shall be the responsibility of the occupant.

The exterior of air condition units shall be wet wiped/HEPA vacuumed. The air condition units shall then be pulled into the interior space where the grills and unit shall be HEPA vacuumed and wet wiped.

5. A thorough visual inspection shall verify the absence of visible dust accumulations. Additional clean-up procedures shall be performed where visible dust is observed. Air sampling shall be performed after the area is free of dust accumulations.

6. Personal air monitoring shall be perfonned in accordance with USDOL OSHA requirements. In addition, personal air monitoring shall be perfonned on a minimum of one worker per shift during the clean up activities for the first ten (10) units. There after at least one personal sample shall be taken on employees cleaning every other unit. The results of this sampling shall be shared immediately with OSHA, the employer and the workers or their representatives. These results shall be also submitted to the USEPA for review and shall . include al a minimum the date and hours of sampling, name of the worker, his/her NYCDEP

v'K)'" L/' NYC-WTC_000151297

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000151297Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000151127 · Box DEP Box 11

A notice instructing that original World Trade Center documents must be preserved as evidence and not disposed of due to potential legal actions.

Filed in the same folder

NYC-WTC_000151141 · Box DEP Box 11

Letter confirming contractor responsibility for cleaning residences and HVAC systems in accordance with project scope.

Filed in the same folder

Compare copies and versions →