Indoor Clean-up Activities Scope of Work

Application: These procedures apply to the clean-up of minimal dust accumulations (light coating). Cleaning shall include HEPA- vacuuming and wet-wiping. If a visual inspection indicates the presence of large debris accumulations fi-om the collapse of the WTC, then these procedures shall not be applicable.

1. All work shall be performed by a NYS DOL licensed contractor with NYS DOL- and NYC DEP- certified workers. The clean-up activities must be performed in the presence of an authorized individual/occupant who shall be responsible for personal belongings.

2. A third party air monitoring firm shall perform air sampling after the clean up activities. The person who conducts sampling shall possess a valid NYS DOL certificate.

3. Individuals performing clean up activities are not required to wear personal protective equipment or respirators.

4. All surfaces shall be wet wiped/HEPA vacuumed. An encapsulating agent shall not be applied. Surfaces include but are not limited to walls, floors, ceilings, ledges, trims, furnishings, appliances, equipment, etc.

Carpets, curtains, upholstery, and other materials that cannot be cleaned by wet wiping shall be HEPA vacuumed two times. Dry sweeping is prohibited. Plants shall be cleaned by rinsing leaves with water. Paperwork and books shall be HEPA vacuumed.

The exterior of air condition units shall be wet wiped/HEPA vacuumed. The air condition units shall then be pulled into the interior space where the grills and unit shall be HEPA vacuumed and wet wiped.

5. A thorough visual inspection shall verify the absence of visible dust accumulations. Additional clean-up procedures shall be performed where visible dust is observed. Air sampling shall be performed after the area is fi-ee of dust accumulations.

6. Personal air monitoring shall be performed in accordance with USDOL OSHA requirements. In addition, personal air monitoring shall be performed on a minimum of one worker per shift during the up activities for the first ten (10) units. These results shall be submitted to tl^,USEPA'^for review and shall include at a minimum the date and hours of sampling, name zdf the worker, his/her NYCDEP asbestos certification number, and specific description of X activities in the unit during the sampling.

P'L- •

NYC-WTC_000148104

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148104Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000141478 · Box DEP Box 05

Fax cover sheet from the Department of Environmental Protection addressed to EPA Region 2 regarding WTC environmental matters.

Similar indexed content

Compare copies and versions →