Identifying asbestos in non-friable bulk samples, lab guidance

Machine-extracted title · confidence 44%

Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.

NYC-WTC_000319786–000319795
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPAZOERR (TUE) 1 2. 1 1 ■ 01 9:29ZST. 9 : 1 7ZN0. 486 1 202484 P 2

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL ...............

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 25 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

8.4.1. Refractive Index Media. The refractive index medium (oil or solid) used to prepare slides must be calibrated to within 0.005 with certified refractive- index solids or a refractometer -This must be performed when the ^gml container is first opened for use and thereafter at three-month intervals. Record: Date, nominal refractive index, measured refractive index, temperature. 8.4.2. PLM Alignment. The PLM must be aligned daily to achieve illumination as close to Kohler illumination as possible and centered through the substage condenser and iris diaphragm. The stage's rotation axis must be centered with the appropriate objectives. Analyzer and polarizer must be rotated to maximum extinction with each other and their privileged directions must be oriented parallel to the lines in the fixed ocular cross hairs (or grid) and aligned at 45° to the accessory port. Record: Date, check-off for rotation centering, axial illumination, full extinction and crosshair alignment fixed in the polarizer's privileged direction. 8.4.3. Refractive-Index Colors. Dispersion-staining or Becke-line colors must be determined weekly from the permanent 1.680 mount of amosite (Section 3.14.3). The source of any deviations must be located and corrected. Record: Date, colors or wavelengths perpendicular and parallel to length. 8.4.4. Analytical Balance. 8.4.41. Analytical balances should be serviced by a qualified service organization annually. Record: Service organization sticker with date of service. 8.4.4.2. Analytical balances must be checked in two ranges weekly with class S weights. The ranges selected should reflect routine use of the balance and

CITY_21MC100_012170731

NYC-WTC_000319786

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319786Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →