NYC 9/11 Public Portal Document

FROM US EPAZOERR (TUE) 12. 11’01 9:30/ST. 9 : 1 7ZNO. 486 1 202484 P 3

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL ,

SUBJECT DATE PAGE 0TEM NO.

Transmission Electron Microscope Method for 3/1/97 26 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

the actual class S weights used should test the optical scale at mid-point. Becord; Date, target and actual readings in a tabular format. 8.4.5.Mi!ffle Oyeri.Temperature5on external meters(€itherdirect-temperature displays or graduated potentiometers) should be calibrated quarterly (Section 3.7.2). This must be a three-point calibration covering a temperature range of at least 450° to 480°C. If a thermometer is used for calibration, the thermometer bulb should be immersed in a sand bath. Record: Date, target temperature, measured temperature in a tabular format. 8.4.6. HEPA-Ventilated Sample Preparation Enclosure. Flow rate at enclosure opening must be measured twice annually to the nearest 5 fpm. Flow rate must not be less than 75 fpm. Record: Date, flow rate. 8.4.7. Transmission Electron Microscope 8.4.7.1 Magnification: Both phosphor viewing screen and micrograph negatives (and/or other hard-copy media) must be calibrated once a month using a calibrated carbon-replica grating at routinely used magnification(s) for accurate measurement of particle dimensions. The calibration system must ensure that 0.5-pm structures (air and water analyses), 5-jjm structures (air analysis), and 10-pm structures (water analysis) can be measured with an accuracy of 5% or better at routinely used magnifications. Record: Nominal TEM magnification(s) vs. a) actual magnification on phosphor screen and b) actual magnification on micrograph negative. Additionally, calibration record must include conversion factors or lengths/diameters of markers on screen used for measuring 0.5 pm, 5 pm

CITY_21MC100_012170732

NYC-WTC_000319787

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319787Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →