NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗EPA/DOE manual describing identification of asbestos in non-friable bulk materials.
NYC-WTC_000319762–000319785OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
(TUE) 1 2. 1 1’ 01 9:27/ST. 9 : 1 1/NO. 4 861 20248 3 P 25 FROM US EPA/OERR
ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL
SUBJECT DATE PAGE STEM NO.
Transmission Electron Microscope Method for 3/1/97 24 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples
8.3. Contamination Control. 8.3.1. Prevention. The laboratory must detail its methods for preventing cross " cohtamihation of eq uipTneht, supplies and reagents. Much of this will be careful cleaning of work area, equipment and supplies. Intensity and frequency of this effort should be based on experience gained through any contamination detected as described in 8.3.2. 8.3.2. Monitoring. The laboratory must have a routine procedure for monitoring contamination of laboratory equipment, supplies and work stations and for resolving contamination problems when discovered. At least one asbestos-free NOB must be prepared and analyzed with every 20 samples analyzed. This non-ACM must go through the full preparation and analysis regimen for the type of analysis being performed. If asbestos is detected, the source of contamination must be traced and the problem resolved to prevent recurrence. Any of the previous samples that may have had results affected by the contamination must be reanalyzed and the client notified of any revisions to reported values. Detailed records of monitoring must be maintained. 8.4. Calibration. Written records for calibration of the following equipment and supplies must be kept. All calibrations listed below (unless otherwise noted) must be performed under the same analytical conditions used for routine asbestos analysis and must be recorded in a bound notebook and include date and analyst's signature. Frequencies stated below may be reduced to "before next use" if no samples are analyzed after the last calibration period has expired. Likewise, frequencies should be increased following non-routine maintenance or unacceptable calibration performance.
CITY_21MC100_003050120
NYC-WTC_000319785
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250730
EPA memo documenting issues with asbestos testing standards post-WTC collapse.
5 shared non-person entities · 1 shared topics · similarity 0.941
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363857
Letter/report about bulk dust/debris sampling on building setbacks for Insignia ESG at a NYC building.
2 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342629
Summary of bulk and TEM sampling with lab analysis and quality control.
9 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390391
Bulk sampling of debris from the roof to determine asbestos content.
2 shared non-person entities · 1 shared topics · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409508
Documentation of sampling and transfer of asbestos samples from Building 200 per EPA guidelines.
9 shared non-person entities · 1 shared topics · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367022
TEM asbestos analysis report for 11/15/01 sample 01-2200, 99 Battery Place.
5 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357500
Summary of analytical results for asbestos by PLM for a NYC site, Sept 2001.
7 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
9 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357497
PLM analytical results for asbestos at 3 World Financial Center Floors 3-26.
7 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
9 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
9 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455928
CoC/documents for asbestos-containing exterior sealant/caulking materials for DDC school task force, June 2001.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000319786
Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.
Similar indexed content
NYC-WTC_000363857
Letter/report about bulk dust/debris sampling on building setbacks for Insignia ESG at a NYC building.
Similar indexed content
Summary of bulk and TEM sampling with lab analysis and quality control.
Similar indexed content
NYC-WTC_000390391
Bulk sampling of debris from the roof to determine asbestos content.
Similar indexed content
NYC-WTC_000250730
EPA memo documenting issues with asbestos testing standards post-WTC collapse.
Similar indexed content