Identifying asbestos in non-friable bulk samples, lab guidance

Machine-extracted title · confidence 44%

Laboratory guidance on analyzing non-friable asbestos-containing materials and PLM alignment.

NYC-WTC_000319786–000319795
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPA/OERR (TUE) 1 2. 1 1 ' 01 9:32/ST. 9 ; 1 7/NO. 486 1 202484 P 6

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE OTEM MO.

Transmission Electron Microscope Method for 3/1/97 29 of 34 198.4 Identifying and Quantitating Asbestos in Non- FnableOrganicaHyBouridBylk SarnpIes^^

calculations of k and sensitivity factors. 8.4.8.4. Ma Sensitivity; The low-energy sensitivity of the detector must be verified every three months by producing resolvable Wa ka X-ray peaks from TEM-grid-mounted NIST SRM 1866 crocidolite. Record: Dated and signed hard copy of 0-10 keV spectrum with resolvable Na ko x-ray peak in notebook. 8.4.8.5. Chrysotile Fibril Sensitivity: The small-structure sensitivity of the detector must be verified every three months by producing resolvable Mg and Si k^ peaks from a single fibril (maximum diameter ^0.05 pm) of TEM- grid-mounted NIST SRM 1866, 1876a. or 1876b chrysotile. Record: Dated and signed hard copy of 0-10 keV spectrum with resolvable Mg k„ and Si peaks with attached electron micrograph of fibril image in notebook. 8.5. Personnel. The laboratory must assure that all analysts are competent to perform TEM and/or PLM analysis of asbestos in bulk samples. TEM analysts must be familiar with the theory and interpretation of electron diffraction and understand the relationship between fiber orientation and diffraction orientation In their TEM. PLM analysts must be familiar with the theory of dispersion staining and the measurement of refractive indices by the Becke line technique and be able to apply these. A personnel file must be maintained for every analyst and must include; 8.5.1. Resume, Each resume must Include formal education, experience and other pertinent information. 8.5.2. Training. Both classroom and in-house training must be detailed to

CITY_21MC100_012170735

NYC-WTC_000319790

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319790Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →