Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPA/OERR (TUE) 1 2. 1 1 ■ 01 9:14/ST. 9 : 1 1/HO. 486 1 202483 P 4

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 3 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

asbestos fibrils. In fact, the then-theoretical 020 (4.5 A) and 002 (7.3 A) spacings of the scrolled fibrils were dramatically revealed in cross sections more than 20

y years ago by TEM (Yada 1969,1971). Furthermore, identification of chrysotile or amphibole crystalline structure can be consistently produced via the electron­ diffraction capabilities of modern TEMs. Finally, the five amphibole types can be differentiated based on their elemental composition when energy-dispersive x-ray analysis (EDX) is utilized. The major drawback to TEM is accurate and reproducible subsampling; since only -'IO* of the original sample is viewed via TEM, extreme precautions must be taken to prevent potentially enormous subsampling bias. 2. Application. Friable materials must be analyzed by one of the point-counting methods (ELAP Item 198.1) while NOBs must be analyzed by one of the gravimetric matrix reduction methods, either the PLM method (ELAP Item 198.1) or the TEM method described herein. This TEM method is the only method that can be used to report true negative results from NOB samples to clients. 3. Equipment and Supplies The following items must be available for sample preparation and analysis in laboratories that analyze bulk samples by TEM: 3.1. HEPA-ventilated, negative-pressure sample preparation work area. This can be a laminar-flow safety cabinet or a similar enclosure that draws all air from the enclosure through a HEPA filter. This should minimize cross contamination and maintain a safe work environment. A flow rate of at least 75 fpm should be maintained at the opening. 3.2. Low-power (10-45X) stereobinocular microscope with external light source for gross examination.

CITy_21MC100_003050099

NYC-WTC_000319764

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319764Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →