Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPA/OERR (TUE) 1 2. 1 1 ■ 01 9:16/ST. 9:11/140.4861 202483 P 7

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE 0TEIV1 NO.

Transmission Electron Microscope Method for 3/1/97 6 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

silicon must be calculated. For example, the ranges of Na;Si, Fe;Si, and Mg;Si would have to be calculated for crocidolite and be available to the TEM analyst. At least four asbestos "look-alikes" must be on separate in-laboratory TEM grids. From these, the laboratory must have produced electron micrographs of images, electron diffraction patterns, and EDX spectra. The criterion or criteria that differentiate each of these from asbestos must be highlighted. 3.13.6. Zone;Aids References; The laboratory must have tables or software that will allow determination of specific zone-axis measurements for each asbestos type. 3.13.7. Darkroom Supplies; If the laboratory is using photographic methods to produce images and ED patterns, supplies must be on hand to process these images. 3.14. Reference materials. 3.14.1. National Institute of Standards and Technology (NIST) SRMs 1866 and 1867; 3.14.1.1. Chrysotile. 3.14.1.2. Amosite (grunerite). 3.14.1.3. Crocidolite (riebeckite). 3.14.1.4. Fibrous glass. 3.14.1.5. Anthophyllite. 3.14.1.6. Tremolite. 3.14.1.7. Actinolite. 3.14.2. Verified quantitative standards. All laboratories must have at least 10 different VAT specimens that have been analyzed by an ELAP-certified TEM

CITy_21MC100_003050102

NYC-WTC_000319767

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319767Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →