NYC 9/11 Public Portal Document (TUE) 12. 11'01 9:15/ST. 9 : 1 1/NO. 486 1 202483 P 6 FROM US EPA/OERR

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 5 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

3.11. Ultrasonic bath. 3.12. Filtered (0.1-pm) distilled water. 3.13. References. 3.13.1. Copy of Chatfield (1991) method. 3.13.2. Copy of non-mandatory analytical section of AHERA (1987). 3.13.3. Textbook or reference book on mineralogy or crystallography, e.g., McCrone 1980, McCrone 1988, Deer, Howie and Zussman. 1966. 3.13.4. References required as part of AHERA analysis (e.g., verified asbestos analysis, spot-size measurement, k-factor determination). 3.13.5 Reference Library: The laboratory must develop its own collection of reference materials and information on all asbestos types and other fiber types that commonly interfere with asbestos analysis by TEM. This information must be readily available to all TEM analysts. Electron micrographs (at routine magnification) of images and zone-axis ED patterns (at routine camera length) of single fibrils must be collected for all asbestos types with the laboratory's in­ house TEM. From these electron micrographs, analysts should be able to predict the orientation of ED layer lines relative to the orientation of the fiber at normal TEM operating conditions. Photographic enlargements of these ED patterns should have the characteristic diffraction points and fiber axis orientations labeled. Additionally, hard-copy EDX spectra of each of the asbestos types must be produced using the in-house TEM/EDX system. Using the in-house TEM/EDX system, spectra must be collected from six different fibers of each of the asbestos types. On the basis of these spectra, ranges of ratios (FWHM) of critical cations for each of the asbestos types relative to

CITY_21MC100_003050101

NYC-WTC_000319766

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319766Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →