Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPA/OERR (TUE) 1 2. 11’01 9:16/ST. 9 : 1 1/NO. 486 1 202483 P 8

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 7 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

laboratory (own lab or outside lab) using the quantitative method outlined herein. Raw gravimetric data and calculations used to determine percentages of each component (organic, carbonate, insoluble inorganic, and asbestos) must be provided by the outside laboratories and kept on file. Each of these reference specimens should initially exceed 50 cm^ in area. Sections of these VATs must be submitted blindly as routine samples as outlined in Section 8.2.3 to determine the accuracy and precision of the laboratory's current analytical capabilities. 3.14.2.1. Negative (non-ACM) standards. At least two negative standards must be kept. While one of these may contain asbestos at a concentration of less than 1 %, the other must be free of any asbestos for use in monitoring contamination (Section 8.3.2). 3.14.2.2. Positive (ACM) standards (low concentration). At least two positive standards with concentrations less than 10% must be kept. 3.14.2.3. Positive (ACM) standards (high concentration). At least two positive standards with concentrations greater than 10% must be kept. 3.14.2.4. At least four other different standards must be kept. 3.14.3. Permanent mount of NIST amosite in nD=1.680. 3.15. Microscope slides. 3.16. Cover slips. 3.17. Refractive index liquids; 3.17.1. 0^=1.550 high dispersion. 3.17.2. nD=1.605 high dispersion. 3.17.3. nD=1.630 high dispersion.

CITY_21MC1OO_OO3O5O1O3

NYC-WTC_000319768

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319768Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →